Встроенный контроллер BLDC 380-400


Поделиться:


Цена:22 292,43 ₽ - 66 877,29 ₽*

Количество:



Описание и отзывы


Трекер стоимости

Месяц Минимальная цена Макс. стоимость
Sep-18-2025 26527.81 $* 27853.21 $*
Aug-18-2025 26305.41 $* 27620.81 $*
Jul-18-2025 22069.9 $* 23172.39 $*
Jun-18-2025 25859.39 $* 27152.43 $*
May-18-2025 22515.35 $* 23641.46 $*
Apr-18-2025 25413.81 $* 26684.4 $*
Mar-18-2025 25190.42 $* 26450.10 $*
Feb-18-2025 24967.96 $* 26215.7 $*
Jan-18-2025 24744.65 $* 25981.97 $*

Характеристики

Product Display

_01.jpg

HF-MOTOR_01.jpgHF-motor_02.jpg

 

Motor typeOutput PowerVoltageLoadSpeedRated TorqueEfficiencyNoiseIP Class
KWVARPMNm%dB
VOL- IEC90S2250-2P2.25220 ac6.4230007.169262IP 54
VOL- IEC100S2250-4P2.25220 ac6.42150014.339262IP 54
VOL- IEC112S2250-6P2.25220 ac6.42100021.489262IP 54
VOL- IEC112S3750-2P3.75220 ac10.70300011.9492.562IP 54
VOL- IEC112S3750-4P3.75220 ac10.70150023.8892.562IP 54

HF-custom.jpg

motor.jpg

 

VIEW MORE PLS CONTACT US >>>

 

 

Other Products

_03.jpg

Process Flow

_04.jpg 

About Us

_05.jpg_06.jpg 

Packing&Transport

_07.jpg

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

 

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

 

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

 

      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.

 

Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.

 

     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.

 

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

 

Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.

 

     Likely cause: Brushes are worn.
     What to do: Verify brush length.

 

     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.

 

Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.

 

Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.