Поделиться:
Месяц | Минимальная цена | Макс. стоимость |
---|---|---|
Sep-16-2025 | 0.1 $* | 0.75 $* |
Aug-16-2025 | 0.15 $* | 0.82 $* |
Jul-16-2025 | 0.2 $* | 0.75 $* |
Jun-16-2025 | 0.88 $* | 0.14 $* |
May-16-2025 | 0.33 $* | 0.4 $* |
Apr-16-2025 | 0.11 $* | 0.93 $* |
Mar-16-2025 | 0.45 $* | 0.30 $* |
Feb-16-2025 | 0.77 $* | 0.82 $* |
Jan-16-2025 | 0.17 $* | 0.95 $* |
Model | BK-GC901 | ||
Oven | Temp. Range | RT+5~450℃ | |
Temp. Accuracy | ≤±0.01℃ | ||
Temp. Program | 16-phase | ||
Max. Temp. Heating Rate | 40℃/min | ||
Time Range | 0-999.9min | ||
Detector | Hydrogen Flame Ionization Detector (FID) | Detection limit:≤5×10-12g/s (100ng/ul n-hexadecane-isooctane solution) | |
Temperature 450℃ | |||
Compatible with packed and capillary columns | |||
Baseline drift:≤2x10-13A/30min | |||
Baseline noise: 3×10-14A | |||
Linear range:≥107 | |||
Thermal Conductivity Detector (TCD) | Sensitivity: >5000mv.ml/mg (50mg/ml toluene-benzene solution) | ||
Temperature 400℃ | |||
Baseline drift:≤0.1mV/30min | |||
Baseline noise: 0.03mV | |||
Linear range:≥105(±10%) | |||
Electron Capture Detector (ECD) | Detection limit:≤1×10-14g/ml (Sample: n-hexadecane δ-666) | ||
Linear range: ≥104 | |||
Flame Photometric Detector (FPD) | Detection limit:≤5×10-12g/s(S of 10ng/uL methyl parathion-ethanol solution) Detection limit:≤4×10-12g/s(P of 10ng/uL methyl parathion-ethanol solution) | ||
Linear range (S): ≥103 Linear range (P): ≥104 | |||
Temperature 350℃ | |||
Nitrogen and Phosphorus Detector (NPD) | Detection limit:≤1×10-12g/s (Azobenzene) Detection limit:≤1×10-12g/s(Marla sulfur phosphorous) | ||
Linear range: ≥103 | |||
Injection Method | Capillary column split/splitless sampling (with diaphragm purging function), packed column sampling, valve sampling, gas/liquid automatic sampling system, etc. | ||
Inlet | 1~4, up to 3 capillary column inlets | ||
Injection Type | Packed column injection, capillary column injection. (Flow setting range: 0~1000ml/min) | ||
Control Accuracy | Pressure: 0.01KPa; Flow: 0.01ml/min | ||
Maximum Split Ratio | 1:999 | ||
Pressure Sensor | Accuracy: <2% of full scale; Repeatability: <± 0.05KPa; Range: 0~0.6MPa | ||
Flow Sensors | Accuracy: < 5% of full scale; Repeatability: 0.5K Pa (full scale); Output offset (accuracy): ±5% | ||
Sampling Valve | Can be equipped with multiple imported automatic control valves, which can run automatically in sequence | ||
Power Supply | AC220V±10%, 50/60Hz | ||
Standard Accessory | FID detector, Chromatography workstation software, Capillary sampler | ||
Optional Accessory | Sample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column. | ||
Package Size (W*D*H) | 750*710*720 mm | ||
Gross Weight | 70kg |