Characteristic | Value | |
Power generator EMEAN model | VG-F110 with soundproof hood | |
Article no. | VG-F110 with hood | |
Three-phase - 400 V. | ||
(Maximum power) kW / kVA | 88kw/110kva | |
(Continuous output) kW / kVA | 80kw/100kva | |
Performance data | ||
Voltage volts | 400/230/380 | |
Frequency Hz | 50/60 | |
Power factor cos ϕ | 0.8 | |
Engine | ||
Manufacturer | FAW (Optional Cummins.perkins, Weifang, Yuchai, etc.) | |
Model | CA6DF2D-14D | |
Fuel | Diesel | |
Speed rpm | 1500/1800 | |
Cylinder | 6 | |
Cooling system | water | |
Starter | electric | |
Consumption | ||
Fuel consumption at 75% load (l / h) | 14.4 | |
Fuel capacity tank (l) | 168.0 | |
Running time at 75% load (h) | 11.6 | |
Measures and Weight | ||
Length (mm) | 2800 | |
width (mm)) | 1100 | |
Height (mm) | 1500 | |
Weight, dry (kg) | 1500 | |
Protection classes | ||
Great | H | |
IP protection class | 23 | |
Noise emission Optional | ||
Sound pressure in 7 m DB (A) | 60-75 |
Manual control - MCP | Automatic control panel - ACP | |
A manual control is mounted on the generator including displays, monitoring and connectors with protective devices. | Mounted in the control unit of the power generator Control AC03 for control and Monitoring for emergency power operation. Lockable Door with viewing window in front of the Control panel. | |
◆ Start / stop and preheating by means of a key switch ◆ Not-Emergency stop button | ◆ Operating modes: Off, manual, automatic, test ◆ Button for mains and generator switch control ◆ emergency stop ◆ Remote start ◆Control voltage main switch ◆ battery charge retention ◆ RS232 interface ◆ Audible alarm ◆ Password protection for parameter settings | |
◆ Alternator failure ◆ Low oil pressure ◆ engine temperature ◆ Earth fault current | ◆ Motor protection: Low oil pressure, Engine temperature ◆ Generator: under / over voltage, overload, under /Overfrequency, start failure, battery voltage | |
◆ alternator ◆ alternator ◆ High engine temperature ◆ short-circuit release (3-pole circuit breaker) | ◆ Motor protection: Low oil pressure, Engine temperature ◆ Generator: under / over voltage, overload, ◆ 3-pole circuit breaker ◆Earth fault current | |
◆ voltmeter (1-phase) ◆ ammeter (1-phase) ◆ Hour meter | ◆ Grid parameters voltage, frequency ◆ Grid power and CosPhi ◆ Generator voltage (3-phase true RMS) ◆ generator frequency ◆Generator power and Cosphi (kW, kVA, kVAr) ◆ battery voltage ◆ Operating hours and engine statistics ◆ all available motor parameters and speed ◆ tank capacity% | |
◆ Lockable door with viewing window in front of the control panel | ◆ Lockable door with viewing window in front of the Control panel | |
Optional | ||
◆ 1x 63A - 400V / 5-pole CEE ◆ 1x 32A - 400V / 5-pole CEE ◆ 2x 16A - 230V / 3-pole CEE ◆ 1x 16A - 230V / SCHUKO | ◆ 1x 63A-400V / 5 pole CEE ◆ 1x 32A-400V / 5 pole CEE ◆ 2x 16A-230V / 3 pole CEE ◆ 1x 16A-230V / SCHUKO | |
Stromgenerator_EMEANG_SW_ Manuel_Panel_01 | Stromgenerator_EMEAN_GSW_ Automatic_Schalttafel_ACP_01 |
Control panel | ||
Branded high quality digital controlpanel rise the reliability and stabilityof the genset | ||
AUTOMATIC SHUTDOWN AND FAULT CONDITIONS Under/over speed; fail to start High engine temperature; fail to stop Low oil pressure; charge fail Under/over generator volts; over current Under/over generator frequency; emergency stop Under/over mains frequency Under/over mains voltage Low/high battery volts |
PerkIns Englne | Termlnal Wlre Box | Alr Intake |
International branded engine have longer uselife with global after-sale service. | Regular internal wire connection to convenientmaintain. | Ventilation compartment ensuring steady airintake with reduce noise levels. |
Cable Wlnlng | Raln Cover | Acess |
Cable wire with insulation tube to use moresafely. | Strong materials cover to avoid rain anddopant in the genset to make sure generatorwork regularly. | Large canopy doors for convenient maintainand inspection purposes |