Характеристики


 


Product Description


 




Bante950


Precision Conductivity/TDS/Salinity/Resistivity/°C/°F Meter


950.jpg


Bante950 is a professional multi-range conductivity meter which used for measuring the conductivity, TDS, salinity and resistivity of liquids.


 


Features:



  • Up to 5-point push-button calibration allows user to uses customized calibration solutions.

  • Adjustable TDS factors, cell constants, temperature coefficients and normalization temperature.

  • In salinity measurement modes, selectable practical salinity (PSU) or seawater measurement standard (ppt).

  • Automatic Temperature Compensation (ATC) ensures highly accurate measurements over the entire range.

  • Manual temperature calibration provides accurate temperature value.

  • Selectable either temperature units between degrees Celsius (°C) and degrees Fahrenheit (°F).

  • Selectable linear or pure water compensation modes.

  • Calibration due reminder prompts you to calibrate the meter regularly.

  • Automatic endpoint function freezes the stable measured values for easy reading and recording data.

  • Help message as a operational guide to helps you understand how to use meter.

  • Setup menu lets user customize calibration points, stability conditions, temperature units, date and time to meet measurement requirements.

  • Reset function can resumes all settings to factory default values.

  • Expanded memory stores and recalls up to 500 readings.

  • Built-in real-time clock stamps stored data to meets GLP standards.

  • Stored data can be transferred into computer via USB communication interface.


 


Specifications:


 























































































































































ModelBante950
   Conductivity Range0~20mS/cm (Max.200mS/cm)
   Conductivity Accuracy±0.5% Full Scale
   Calibration PointsUp to 5 points
   Calibration Solutions10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
   TDS Range0~10ppt (Max. 20ppt)
   TDS Accuracy±1% Full Scale
   TDS Factor0.1~1.0 (Default 0.5)
   Salinity Range0~10ppt (Max. 80ppt)
   Salinity Accuracy±1% Full Scale
   Salinity Measurement ModesPractical Salinity (PSU) or 
Seawater Measurement Standard (ppt)
   Resistivtiy Range0~100MΩ
   Resistivtiy Accuracy±1% Full Scale
   Resolution0.001, 0.01, 0.1, 1, Automatic
   Temperature Range0~105°C, 32~221°F
   Temperature Accuracy±0.5°C, ±0.9°F
   Temperature CalibrationManual
   Temperature Compensation0~100°C, 32~212°F, Automatic or Manual
   Temperature Coefficient0.0~10.0% per °C
   Compensation ModesLinear or Pure Water
   Cell ConstantK=0.1, 1, 10, Selectable
   Normalization Temperature20°C or 25°C
   Auto-OffManual or Automatic 
(10, 20, 30 minutes after last key pressed, Selectable)
   Hold FunctionManual or Automatic
   Stability ConditionsLow or High, Selectable
   Calibration due reminder0 to 30 days
   Reset FunctionYes
   Sensor TypePlatinum (Order Code: CON-0.1, CON-1 or CON-10)
   Connector6-pin
   Memory500 data sets with Date/Time stamping
   OutputUSB Communication Interface
   LCD DisplayCustom dual-display LCD (130×110mm)
   Power RequirementsDC5V, using AC adapters, 220VAC/50Hz
   Dimensions210(L)×188(W)×60(H)mm
   Weight1.2kg

 


Certifications


product certificates.jpg 





HOT SALE ITEMS


dzf 6053_.jpgLS-HD__.jpgQ1000+__.jpgW118A__.jpg


722N_.jpgBiolum-III_.jpg


 





Packaging & Shipping


This year Shipping shows:


 


Packing Details: Standard export packing and neutral packing if needed, carton box, wooden case or upon request, packing carefully.


Delivery time: Within 15 working days after the receipt of payment.


Shipping Method: Air / Sea / Express: DHL TNT FedEx UPS EMS, etc.


packing & shipping.jpg 





Company Information


company introduction.jpg 





Buyer feedback


buyer feedback .JPG 





FAQ


Q: Can you do OEM service ?


A: We can provide the specific products needed around the world at significantly lower costs. 


CHINCAN also offers a Private Labeling Program to provide high quality lab supplies at lower prices.


 If you need further information regarding our OEM or Private Label programs, please contact us freely.


 


Q: How long is your delivery time?


A: Usually, delivery time is 10-15 days depend on the order quantity &  inventory.


 


Q: How about your quality warranty ?


A: Normally all CHINCAN products are supplied with a warranty of 12 Months from the date of shipment.


 


Q: What is your terms of payment ?


A: Payment 100%  T/T, Western Union, L/C, Trade Assurance, Credit Card ect. in advance ,before shippment.





Contact Us