Viatom FS20C Medical Diagnostic Finger SPO2 Oximetro Saturometro Fingertip Oximeter Pulse
pulse oximeter simulator
Classification |
Type of protection against electric shock |
II (Internally powered equipment) |
Degree of protection against electric shock |
Type BF-Applied part (non-defibrillation proof) |
Operating mode |
Spot checking |
Degree of protection against hazards of explosion |
Ordinary equipment: Not protected |
Equipmen type |
Fingertip oximeter |
Measurement Specifications(Spo2 declared accuracy) |
Range(a*) |
70%~ 99%±2digits
0% ~ 69%: unspecified
|
Resolution |
1% |
Update Period |
1s |
Averaging Time |
8s |
PR declared accuracy |
Range(a*) |
25~250 : ±3digits |
Resolution |
1 bpm |
Update Period |
1S |
Averaging Time |
8s |
Power Requirements |
Specification of alkaline batteries |
Two AAA |
Power Requirements |
Less than 30mA |
Operating current |
600 spot checks on two full power batteries at ambient temperature |
Run time |
25°C |
Environmental Specifications |
Temperature Operating |
+410to+104°F/50to+40°C |
Temperature Storage/Transportation |
-40° to +140°F / -40° to +60°C |
Humidity Operating |
10~95%, noncondensing |
Humidity Storage/Transportation |
10-95%, noncondensing |
Atmosphere Pressure Operating |
70-106kpa |
Atmosphere Storage/Transportation |
50~107.4kpa |
Physical Specifications |
Width*Height*Depth |
62x35x31 mm |
Weight |
60 g (including the batteries) |
Display |
Display type |
Dual cdor OLED, 0.96", 128x64 pixel |
Display content |
SpO2%, Pulse rate, Battery indicator; Bar graph , Pulse waveform, Heart beat mark |
LED Wavelengths(Probe LED Specifications) |
|
Wavelength |
Radiant Power |
RED |
660±2nm |
1.8mW |
IR |
906±10nm |
2.0mW |
1.What's SpO2?
SpO2 means the saturation percentage of oxygen in the blood.
2.What's the normal range of SpO2 value for healthy people?
The normal range varies by individual, but usually over 95%, otherwise, please consult your physician.
3.Why do the display value of SpO2 and PR vary with time?
The measured SpO2 and PR value changes in correspondence with the change of patient's physiological conditions.
4.What to do if there is no SpO2 and PR reading?
Do not shake the finger, and keep calm during the measurement. Please also avoid the Oximeter and the cuff on the same limb for blood pressure and oxygen saturation measurement simultaneously.
5.What to do if the Oximeter is moistened or sprayed by water?
Remove the batteries immediately and dry the Oximeter completely with a hair dryer.
6.How to confirm that the SpO2 reading is true or accurate?
Hold breath for a while (50 seconds or more), if the SpO2 value significantly decreases, it means that the SpO2 reading truly reflects the physiological condition change.
7.When to replace the batteries?
The icon of low battery will appear on the screen when the battery voltages are low. By then, batteries need to be replaced.
8.Can I have a sample order for the product?
A: Yes, sample order is supportive
9. What about the lead-time?
A: It takes 3~5 days for sample request and 7~10 working days for mass production.
10. Do you have any MOQ limit for the product order?
A: Low MOQ depends on different models. Sample Demo unit is at least 1 PCS.
11. How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or TNT. It usually takes 5~7 days to arrive. Shipping by Air or by Sea is optional.
12. How to place an order for the product?
A: You can place an order through Alibaba.com, we have territory account manager to support you.
13. Is it OEM with my brand on the product?
A: Yes. It depends on business volume. For the details, please check with our territory account manager.
14.What factors will affect the SpO2 accuracy?
* Intravascular dyes such as indocyanine green or methylene blue;
* Exposure to excessive illumination, such as surgical lamps, bilirubin lamps, fluorescent lights, infrared heating lamps, or direct sunlight;
* Vascular dyes or external used color-up product such as nail enamel or color skin care;d) Excessive patient movement;
* Placement of a sensor on an extremity with a blood pressure cuff, arterial catheter, or intravascular line;
* Exposure to the chamber with High pressure oxygen;
* There is an arterial occlusion proximal to the sensor;
* Blood vessel contraction caused by peripheral vessel hyperkinesias or body temperature decreasing;
* Low perfusion condition (Perfusion Index is small).