D1-A Электрический искровой дефектоскоп праздничный детектор для покрытия


Поделиться:


Цена:*

Количество:



Описание и отзывы


Трекер стоимости

Месяц Минимальная цена Макс. стоимость
Sep-17-2025 0.25 $* 0.87 $*
Aug-17-2025 0.95 $* 0.10 $*
Jul-17-2025 0.18 $* 0.91 $*
Jun-17-2025 0.15 $* 0.65 $*
May-17-2025 0.39 $* 0.97 $*
Apr-17-2025 0.58 $* 0.96 $*
Mar-17-2025 0.11 $* 0.80 $*
Feb-17-2025 0.35 $* 0.94 $*
Jan-17-2025 0.26 $* 0.34 $*

Характеристики


D1-A Electric spark flaw detector,Holiday Detector For Coating Leak Electrospark flaw detector


Functions and use


 


D1 series edm leak detector is used to detect the construction quality of oil and gas pipelines, cables, enamels, metal storage tanks, ships and other metal surface anticorrosion coating and the corrosion point of aging micro holes, air gap of a special detection equipment, is a popular version of the edm detector.


 


Characteristics 


1. Low power consumption, small size and light weight;


2. Simple operation, intuitive and convenient;


3. The pointer head indicates the output voltage and the supply voltage;


 


D1-A Electric spark flaw detector,Holiday Detector For Coating Leak Electrospark flaw detector


Main technical indicators


1. Measurement range: type A: 0.03-3.5mm


B: 3.5 to 10 mm


C: 0.03 to 10 mm


2. Output high voltage: type A: 0.5-15kv


 B: 15 to 35 kv


C: 0.5-35 kv


3. Display: pointer type


4. High voltage control system: regulation of ordinary potentiometer


5. Dc power supply: 12v


6. Power consumption: < 5w


7. Alarm delay: 1-2 seconds


8. High voltage gun: microelectronic high voltage generator


9. Packing: metal case


10. Host size: 165mm×155mm×68mm


11. Main engine weight: 1.5kg (including battery)


 


D1-A Electric spark flaw detector,Holiday Detector For Coating Leak Electrospark flaw detector


Detection principle and method


Leak detection principle: the insulation corrosion layer on the metal surface is too thin, the resistance value and the air gap density are very small, when there is a high voltage after the formation of air gap breakdown and spark discharge, to the alarm circuit to generate a pulse signal, alarm alarm sound and light alarm, according to this principle to achieve the purpose of corrosion detection layer.


 


Instrument accessories









1. One main machine


2. One high-pressure gun


3. One plate probe brush


4. One charger


5. One long grounding wire


6. One short grounding wire


7. Connect one magnet


8. 2 grounding rods


9. One pair of high-pressure gloves


10. One set of random documents



SL-III.jpg