Specifications
No. | Parameters | Values |
1 | Speed | 0-1200rpm |
2 | Torque | 2N.m |
3 | Sterilization temperature | 135℃ |
4 | Noise | ≤75dB |
5 | Operation(V) voltage | 14.4V |
6 | Radial circle run-out | ≤0.1mm |
7 | Axial movement | ≤0.5mm |
8 | Battery capacity | 1600mAh |
9 | Biggest drill bit diameter | 8mm |
10 | Diameter of Cannulation | 4.5mm |
11 | BATTERY | NI-MH |
12 | Color | black/ silver |
Standard Configuration:
1. One handpiece
2. 2 batteries
3. One charger
4. One drill chuck with key
5. One Aseptic transfer kit
6. Aluminum case for option
Feature:
1. Imported motor, stepless speed control
2. long service life, 1 year warranty for handpiece
3. High Coaxiality, Low-Noise
4. Ergonomic design
5. Quick coupling
6. Whole unit can be autoclavable at 135 °C (Improved type ≤ 155 °C ), with 1.6Mpa
Warranty:
Warranty for whole machine is 1 year, for motor is 2 years, for the battery and other fast consumption items is 3 months.
Notes:
1. Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the temperature is over 135 °C, the motor will be damaged.
2. Normal bone drill can only hold drill bits less than 6mm,acetabulum reaming drill with big torque,rpm is around 300,canulate drill is used with nail or K wire ,rpm is around 600.
3. The battery need to be get out of the power tool after surgery.Otherwise the small automatic discharge of the electric will make the life of the battery short.
4. The battery cannot be sterilized ,it is not autoclavable.
5. The cranial bur must be washed right after the surgery by purger in order to avoid the blood stick in the bur,then we should make it dry.
6. The battery space in the handpiece of the tool should not have any water,after sterilization.
7. The cranial bur blade is made of medical stainless steel,in order to avoid broken,so it is flexible and not very hard,it is easy to be attrite,we suggest each blade only use for 1 surgery.
Aluminum case for each set , then into a good quality carton.
As per clients' requirements.
You can contact us via the following ways or inquiry directly on Alibaba.
As we are a professional original factory with CE and ISO13485 certificates
1.You can get technical support directly.
2. Quality assurance with patented technology backup.
3.Stable supply and good warranty.
4.OEM & ODM Provided.
5.You spend less but got more.
Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com