Type | Displacement | Max pressure | Max.speed | Min speed | Dimensions | |||||||||||
P1 | P2 | P3 | M | L | A | B | C | D | a | b | c | d | ||||
cm3/rev | bar | bar | bar | r/min | r/min | mm | mm | mm | mm | mm | mm | mm | mm | |||
BQP3.5/D40 | 40 | 250 | 265 | 280 | 2750 | 600 | 189 | 108 | 60 | 30 | M10 | 32 | 52 | 26 | M10 | 25 |
BQP3.5/D50 | 50 | 250 | 265 | 280 | 195 | 111 | 60 | 30 | 32 | 52 | 26 | 25 | ||||
BQP3.5/D63 | 63 | 250 | 265 | 280 | 500 | 203 | 115 | 60 | 30 | 32 | 52 | 26 | 25 | |||
BQP3.5/D71 | 71 | 230 | 250 | 270 | 2500 | 208 | 117 | 70 | 36 | M12 | 35 | 60 | 30 | 32 | ||
BQP3.5/D80 | 80 | 230 | 250 | 270 | 213 | 120 | 70 | 36 | 35 | 60 | 30 | 32 | ||||
BQP3.5/D90 | 90 | 200 | 230 | 250 | 219 | 123 | 70 | 36 | 40 | 60 | 30 | 32 | ||||
BQP3.5/D100 | 100 | 200 | 230 | 250 | 225 | 126 | 70 | 36 | 40 | 60 | 30 | 32 |
(INSTALLATION NOTES)
Please strictly follow assembly and use indications given in this catalogue for top performance and longer life of BOQUN pump.
INSTALLATION NOTES
Before starting the system on a continuous basis,we suggest to adopt as follows simple precautions.
Check for the direction of rotation of the pump to be consistent with the drive shaft one,be sure no reversion revolved.
Check for the proper aligment of pump shaft and motor shaft,it is necessary that the connection does not induce axial or radial loads.
Check if contact area between seal ring and shaft is clean,remove all dirt,chips and all foreign bodies form flanges connecting inlet and
delivery ports dust could provoke quicker wear and leakage .
Ensure that intake and return pipes ends are always below fluid level and as far from each other as possible
Fill the pump with fluid,and turn it by hand.
Disconnect pump drain during start up to bleed air off the circuit.
Always avoid or limit load starting for pump longer life.