Electrical Rigid Conduit Pipe
SN | Description | Part Number | Size |
1 | pvc conduit pipe | CT001610 | OD16*1.0mm |
2 | CT001612 | OD16*1.2mm | |
3 | CT001614 | OD16*1.4mm | |
4 | CT002010 | OD20*1.0mm | |
5 | CT002012 | OD20*1.2mm | |
6 | CT002014 | OD20*1.4mm | |
7 | CT002016 | OD20*1.6mm | |
8 | CT002018 | OD20*1.8mm | |
9 | CT002512 | OD25*1.2mm | |
10 | CT002514 | OD25*1.4mm | |
11 | CT002516 | OD25*1.6mm | |
12 | CT002518 | OD25*1.8mm | |
13 | CT002520 | OD25*20mm | |
14 | CT003214 | OD32*1.4mm | |
15 | CT003216 | OD32*1.6mm | |
16 | CT003218 | OD32*1.8mm | |
17 | CT003220 | OD32*2.0mm | |
18 | CT003222 | OD32*2.2mm | |
19 | CT004016 | OD40*1.6mm | |
20 | CT004018 | OD40*1.8mm | |
21 | CT004020 | OD40*2.0mm | |
22 | CT004022 | OD40*2.2mm | |
23 | CT005018 | OD50*1.8mm | |
24 | CT005020 | OD50*2.0mm | |
25 | CT005022 | OD50*2.2mm | |
26 | CT005025 | OD50*2.5mm | |
27 | AS pvc conduit pipe | CT001613 | OD16*1.3mm MD Grey |
28 | CT002018 | OD20*1.8mm MD Grey | |
29 | CT002518 | OD25*1.8mm MD Grey | |
30 | CT003221 | OD32*2.1mm MD Grey | |
31 | CT004024 | OD40*2.4mm MD Grey | |
32 | CT005028 | OD50*2.8mm MD Grey | |
33 | CT002023 | OD20*2.3mm HD Orange | |
34 | CT002525 | OD25*2.5mm HD Orange | |
35 | CT003227 | OD32*2.7mm HD Orange | |
36 | CT004031 | OD40*3.1mm HD Orange | |
37 | CT005034 | OD50*3.4mm HD Orange |
Related Products:
Halogen Free Low Smoke Conduit
>> Why choose Low Smoke and Halegen free conduit?
⌊Low Smoke⌋
In case of a fire accident, they ensure better visibility of escape routes due to their low smoke emission.
The common test on smoke release follows IEC 61034.
⌊Halogen Free⌋
In case of fire, halogens generate toxic smoke. Halogen free installation systems ellminate this hazard.
Halogen free conduit don’t release toxic and corrosive gases during combustion, protecting people and
environment. The halogen content of plastics is tested according to EN 50267-2-2.
⌊Flame Retardancy⌋
They contain flame retardants that reduce flame propagating. To aviod flame propagation in buildings,
conduits have to be flame retardant. The relevant standard test is subject to IEC 61386.
(Medium duty & Heavy duty)
Properties:
1) Outer diameter: | φ16, φ20, φ25, φ32, φ40, φ50, φ63mm |
2) Resistance to compression: | 750Nt/5cm or 1250Nt/5cm |
3) Resistance to impact: | 6J |
4)Temperature range: | -45oC+120oC |
5) Resistance to bending: | Rigid |
6) Electrical characteristics: | With electrical insulated characteristics |
7) Fire resistance: | V0 |
8) UV resistance: | UV Stabilized |
9) Color selection: | White/Black/Grey |
10)OEM | Available |