Product Description


 

 VPD-04R under and over voltage protection relay


♥ 5 – 100 KΩ Sensitivity Adjustable.


 00.jpg


Applications: For civilian use water tower, reservoir of water levle control


 


Function Features:


 -Modularization design,width: 36mm;


-Sensitivity: 5 -100KΩ, adjustable, applicable for various liquids;
-With adjustable operation delay to prevent liquip from fluctuating;
-Two operating modes available: bipolar probe and tripolar probe;
-LED indication indicates the state of water level;
-Usable for water supply and drainage;
-Both bolt installation and guide-rail installation realized.


 


Three electrodes are connected to the “U”, ”L” and ”B” terminals.
When the liquid level reaches the upper level electrode (U), then the relay energizes its contacts to turn on the draining pump. The OUT light is turned on.
When the liquid level reaches the lowest level electrode (L), then the relay de-energizes its contact and turns the pump off. The OUT light is turned off.
According to the liquid conductivity, sensitivity(Impedance between electrodes)can be adjusted in the range of 5-100KΩ using the knob on the front side of the relay.


 


The upper level electrode(U)                                                       : Top (U) 
The lowest level electrode (L)                                                      : Bottom (L) 
The earth electrode (B)                                                                 : Earth (B) 


 


Technical Data:

















































Rated Voltage 230 VAC  
Operating Range (0.8-1.1)xUn     Un norminal voltage
Frequency 50/60Hz
Sensitivity 5-100 KΩ adjustable
Contact Current 5-100 KΩ adjustable   Max. 5 A / 240 VAC
Power Consumption <4VA
Device Protection Class IP20
 Connector Protection Class IP00
Ambient Temperature  -5°c to +50°c
Connection Type  Suftace mounted or rail-mounted
Dimensions 36*90*60mm

 


 VPD04R  1.pngVPD04R 3.png