R220Vac 2u ups rackmount 1 phase 19Inch 1Kva2Kva 3Kva 6Kva 10Kva Rack Mount UPS For Server Room
Rack Series 1 ~ 10KVA UPS double conversion pure online architecture, the structure can block abnormal power supply impact on the load, at the same time, it can ensure the stable and reliable output, and make the load run safely. It is the best architecture design that can effectively solve all power problems, the use of digital control technology to provide users with more secure power protection.
Model | H1KR | H1KRS | H2KRS | H3KRS | H6KRS | H10KRS | |
Rated Power | 1KVA/0.9KW | ||||||
Input | Voltage | (110 ~ 300)VAC | (176 ~ 276)VAC | ||||
Frequency | (40 ~ 70)Hz | (46 ~ 54/56 ~ 64)Hz | |||||
Power Factor | >0.99 | ||||||
External battery Standard Voltage | — | 36VDC | 72 | 96 | 192 | ||
Battery Type | Maintenance-free lead-acid battery | ||||||
Battery | Battery Number | 3PCS | — | ||||
Output | Voltage | 220(1±1% )VAC | |||||
Synchronize with Input (Utility Mode) | |||||||
Frequency | 50(1±0.2%) Hz ( Battery Mode ) | ||||||
Overload Capacity | 100%-110%:Only warning sound; | 105%-125%:Automatically turns off after 1 minute, or switches to bypass mode when the input is normal; | |||||
110%-130%:Automatically turns off after 1 minute, or switches to bypass mode when the input is normal; | 125%-135%,30 seconds or switch to bypass mode when the input is normal; | ||||||
>130%:Turn off immediately, or switch to bypass mode when the input is normal. | >135%,Turn off after 0.5 seconds or switch to bypass mode when the input is normal | ||||||
Output waveform | Pure Sine Wave | ||||||
Socket | Universal Socket | Terminal Block | |||||
Others | Transfer Time | 0ms | |||||
Display | LCD Display | LED/LCD Display (Optional) | |||||
Automatic restart | After the battery turns off, the UPS can be automatically restarted when the utility power returns to normal. | ||||||
Warning Alarm | Battery discharge | One beep every 4 seconds when the input voltage is off; one beep per second when the battery is exhausted | |||||
UPS Error | Keep Beeping | ||||||
Connection | RS-232 | Intelligent monitoring functions such as Utility abnormal, power outage, battery capacity, and UPS status indication. | |||||
Option | SNMP card, AS400 card, USB connection | ||||||
Surroundings | Temperature | 0℃~ 40℃ | |||||
Humidity | 20%~ 90% | ||||||
Audible Noise | <55dB | ||||||
Shape parameter | Host size | 482.6*450*88 | 482.6*600*130 | ||||
(W*D*H)mm | |||||||
Battery size | 482.6*450*88 | 482.6*600*130 | |||||
(W*D*H)mm | |||||||
Host weight | 16.3 | 9.1 | 11.5 | 12.3 | 18.5 | 19.5 | |
(Net weight)kg |