Product Description

8.7-15kV, Heat Shrink ,Cable Terminal Kits

Heat shrinkable power cable accessories are provided with the benefits of light weight,reliable application and easy installation.
Suitable for the long-term service from -55℃ to +105℃.Used for the intermediate and terminal joints of oil-immersion cable and cross-linking cable up to 35kV.
Widely applied in industries of electric,power,petrochemical,metallurgy,railway,port and construction,etc.

Detailed Images
\t
Product name
\t
Test item
\t
Test Method
\t
Test result
\t












10kV Heat-shrinkable outdoor termination
\t
AC withstand for 1MIN under rain 1MIN
\t
Neither breakdown nor flashover shall occur at 45kV for rain
\t
No breakdown and flashover occurred on the combination samples at 45kV for 1min
\t
Qualified
\t
AC withstand for 1MIN under rain 1MIN
\t
Neither breakdown nor flashover shall occur at 45kV for rain
\t
No breakdown and flashover occurred on the combination samples at 45kV for 1min
\t
Qualified
\t

Partial discharge test
\t
The magnitude of the discharge at 13KV shall not exceed 20pC.
\t
The magnitude of the discharge of the combination samples didn't exceed 2pc at 13kV
\t
Qualified
\t
Heating cycles voltage test in air
\t
3 cycles at the conductor temperature of 90 to 95℃
\t

Subjected to 3 cycles in air at the conductor temperature of 90 to 95℃
\t

Partial discharge test
\t
The magnitude of the discharge at 13KV shall not exceed 20pC.
\t
The magnitude of the discharge of the combination samples didn't exceed 4pc at 13kV
\t
Qualified
\t

Impulse voltage withstand test
\t
Neither breakdown nor flashover shall occur at 10 positie and 10 negative impulses of 105kV
\t
No breakdown nor flashover occurred on the combination samples at 10 positive and 10 negative impulses of 105kV
\t
Qualified
\t
DC negative polarity voltage withstand for 15MIN
\t
Neither breakdown nor flashover shall occur at 52kV for 15min
\t
No breakdown and flashover occurred on the combination samples at 52kV for 15min
\t
Qualified
\t

AC withstand test for 4H
\t
Neither breakdown nor flashover shall occur at 35kV for 4H
\t
No breakdown and flashover occurred on the combination samples at 35kV for 4H
\t
Qualified