904P Portable Conductivity/Dissolved Oxygen Meter
Multiparameter portable Conductivity/Dissolved Oxygen meter contains 5 measurement modes, the meter is suitable for measuring the conductivity, TDS, salinity, resistivity and DO.
Conductivity/TDS/Salinity/Resistivity Modes:
• Multiparameter portable conductivity/dissolved oxygen meter is equipped with a backlit LCD.
• 1 to 5 points push-button calibration, automatically recognizes the calibration solutions.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations ensure the reliable DO measurements.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Alarm prompts user to calibrate the meter regularly.
• Stability indicator shows when a measurement is recognized as stable.
• Auto-Hold feature senses and locks the measurement endpoint.
• Calibration report provides the details for checking the electrode performance.
• Battery indicator shows the remaining battery capacity.
• Auto-Power Off effectively conserves battery life.
• Setup menu allows setting the 13 parameters, including the number of calibration points,
stability criteria, temperature unit, date and time, etc.
• Reset feature automatically resumes all settings back to factory default options.
• Expanded memory stores and recalls up to 500 data sets.
• Stored readings can be transferred into the computer by USB communication interface.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that use the
meter smoothly.
Model | 904P | |
Conductivity | ||
Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |
Accuracy | ±0.5% F.S | |
Resolution | 0.001, 0.01, 0.1, 1 | |
Calibration Points | 1 to 5 points | |
Calibration Solutions | 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm | |
Temperature Coefficient | 0.0~10.0%/°C | |
Compensation Modes | Linear or Pure water | |
Cell Constant | K=0.1, 1, 10 or Custom | |
Reference Temperature | 20°C or 25°C | |
TDS | ||
Range | 0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) | |
Accuracy | ±1% F.S | |
Resolution | 0.01, 0.1, 1 | |
TDS Factor | 0.1~1.0 (Default 0.5) | |
Salinity | ||
Range | 0.00~80.00ppt, 0.00~42.00psu | |
Accuracy | ±1% F.S | |
Resolution | 0.01 | |
Measurement Modes | Practical salinity (psu) or Natural seawater (ppt) | |
Resistivity | ||
Range | 0.00~20.00MΩ | |
Accuracy | ±1% F.S | |
Resolution | 0.01, 0.1, 1 | |
Dissolved Oxygen | ||
DO Range | 0.00~20.00mg/L | |
Accuracy | ±0.2mg/L | |
Resolution | 0.1, 0.01mg/L, selectable | |
% Saturation of Oxygen | 0.0~200.0% | |
Accuracy | ±2.0% | |
Resolution | 0.1, 1% | |
Calibration Points | 1 or 2 points | |
Pressure Correction | 60.0~112.5kPa, 450~850mmHg | |
Salinity Correction | 0~50g/L | |
Temperature | ||
Range | 0~105°C, 32~221°F | |
Accuracy | ±0.5°C | |
Resolution | 0.1°C, 0.1°F | |
Calibration Points | 1 point | |
Calibration Range | Measured value ±10°C |