Поделиться:
Месяц | Минимальная цена | Макс. стоимость |
---|---|---|
Sep-19-2025 | 0.8 $* | 0.65 $* |
Aug-19-2025 | 0.31 $* | 0.10 $* |
Jul-19-2025 | 0.56 $* | 0.37 $* |
Jun-19-2025 | 0.23 $* | 0.40 $* |
May-19-2025 | 0.41 $* | 0.20 $* |
Apr-19-2025 | 0.23 $* | 0.6 $* |
Mar-19-2025 | 0.91 $* | 0.12 $* |
Feb-19-2025 | 0.9 $* | 0.59 $* |
Jan-19-2025 | 0.56 $* | 0.65 $* |
UPS for IDEAL Choice computer ups
5200C 500VA / 700VA (Universal Nema) backup power
IDEAL 5200C UPS series is cost effective UPS model that offers reliable performance to protect home and office appliance from power failure. It is suitable for users who consider price as first priority. Equipped with 2 steps boost & 1 step buck AVR stabilizer to stabilize output voltage fluctuations and it can correct any abnormal voltages to protect connected loadings. With multi-sockets, it helps users save extra cost for additional power strips. The size of UPS is suitable to place in compact space at home or office. 650VA UPS
* Auto-restart: UPS shuts down upon battery low and restarts automatically upon AC recovery. Line Interactive UPS
* No-load shut down function (UPS Green Mode) for power saving computer ups
* 2-steps boost & 1-step buck AVR to stabilize output voltage
* Constant current, constant voltage battery charger backup power
* UPS automatically charge itself under OFF mode 650VA ups
* Advanced microprocessor control technology Line Interactive UPS
* Lightning / surge protection 175 joules computer ups
* Over / under voltage protection backup power
Advanced microprocessor control technology keeps UPS high performance and reliability, operating effective to reduce energy wasting. 650VA UPS
Built-in 2 steps boost & 1 step buck stabilizer to maintain voltage stability, sensing abnormal voltage and regulating immediately. backup power
Built-in CC charger keep battery charged in Constant Current while charging. 650VA UPS
Built-in CV charger keep battery charged in Constant Voltage after fully charged to ensure battery power. standby ups
Offering completed power protection to guard the connected devices against from surge, over-voltage and under-voltage damage. Line Interactive UPS
The 3 in 1 power switch of UPS has Power ON, Power OFF function, and LED Power Switch can indicate UPS status. UPS
Novelty small-size housing design with multiple Universal Nema sockets on the top case makes UPS portable, space saving and enable to protect your important electronic devices. standby ups
MODEL | IDEAL-5205C | IDEAL-5207C | ||||
CAPACITY UPS | 500VA/250W | 700VA/350W | ||||
INPUT | ||||||
Voltage | 110/115/120Vac or 220/230/240Vac | |||||
Voltage Range | -30% + 25% | |||||
Frequency | 50 or 60Hz (Auto-Sensing) | |||||
OUTPUT | ||||||
Voltage Regulation | AC mode / Battery normal : 110/115/120Vac or 220/230/240Vac +/- 10% | |||||
Frequency | AC mode : 47-53 Hz for 50Hz or 57-63Hz for 60Hz ; Battery mode : 50Hz or 60Hz +/- 1Hz | |||||
Transfer Time | < 6ms(Typical) | |||||
Waveform | Simulated sinewave | |||||
Outlet | Universal Nema *8pcs (4pcs for back-up + 4pcs for surge protected only) | |||||
BATTERY | ||||||
Voltage | 12VDC | |||||
Type | 12V / 4AH*1pc | 12V / 5AH *1pc | ||||
Recharge Time | 5 hours to 90% after complete discharge | |||||
Safety Protection | Over Charge & Over Discharge Protection | |||||
Advanced Battery Management | Yes | |||||
DISPLAY | ||||||
LED Status Indicators | AC normal : Blue ; Battery back-up : Red | |||||
AUDIBLE ALARM | ||||||
Battery Mode | Two short tones every 8 seconds | |||||
Low Battery | Four short tones every second | |||||
Overload | Beeping continuously | |||||
Fault | Beeping continuously | |||||
ENVIRONMENT | ||||||
Operating Temperature | 0℃ - 40℃ (32℉ - 104℉) | |||||
Humidity | 0~95% (Non-condensing) | |||||
Acoustic Noise | <40 dB at 1M | |||||
PHYSICAL | ||||||
Dimension(D*W*H) | 210*131*98 MM |
IDEAL POWER CO., LTD was founded in 1996 and committed to design and manufacture reliable and qualified full range of power products, including Uninterruptible Power Supply (UPS), Inverter, Automatic Voltage Regulator (AVR), Voltage Protector (VP) and Surge Protector (SP).
With more than 20 years' experience of OEM/ODM in power products, IDEAL POWER strives to achieve the mission to provide products with high quality and better performance to meet customers' demand in the world.
We, IDEAL, are dedicating on product development and training professional team, we focus on the global market trend to provide innovative power for customers. IDEAL engineering team has professional background experience and technical knowledge and skill, devoting to integrate global market tendency with new technology to ensure products meet the global customer demand. IDEAL design team help customer design customized product package to establish admirable corporate image for marketing.
We are convinced that establishing long-term relationship of mutual trust and mutual benefit between IDEAL and customers is the motion for us to thrive.
With well-trained and professional team, IDEAL support best service and qualified products to customers globally.
1) ODM/OEM experience for more than 20 years.
2) Well-organized manufacturing bases to meet worldwide growing demand.
3) Customized products to meet various applications.
4) Full range of power products
5) High quality products supported by strict quality control system
6) Well-trained workforce and engineer team.
7) Reliable manufacturing supplier on E-commerce online platform
Q1: Why you should install UPS?
When AC Power is off, UPS will offer emergency back-up power to your electronic devices for data loss protection. Power surges are a threat everywhere. UPS can provide fully power protection for over-voltage, under-voltage and surge to offer smooth and consistent flow of power quality to your appliances.
Q2: What electronic appliances should be protected?
All electronic appliances that need long programming times or have to be always accessible would be better to install with a UPS system. This includes computer, medical equipment, data center, server room, networking system and any important electronic appliances.
However, it is not recommended to connect UPS with laser printer or office multifunction fax/printer because they will draw a high initial inrush current at start-up. A typical UPS cannot deal with such a spike.
Q3: What factors can affect UPS battery life time?
Batteries must be kept at ambient temperature of 25°C (77°F). If battery is operated at higher temperatures, its average life will be shortened. The number and length of battery discharges affect a battery's efficiency to deliver power. The more or deeper discharges, the shorter the battery's life will be.
If a battery is undersized for a load, battery run time and life expectancy will also be shortened.
Therefore, it is recommended to replace the batteries every 3 years after initiating the unit.
Recharge batteries every 3 months is necessary if it is not in use.
Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com