ICD60W Wireless transmitter can be used to measure pH, ORP, conductivity, dissolved oxygen, Ammonia Nitrogen, Ionic Concentration, Turbidity in a variety of process liquids.
The transmitter has a rugged, weatherproof, corrosion-resistant enclosure (IP65) of epoxy-painted aluminum.
It is wireless types and cancel the wiring trouble. It is compliance with the MODBUS protocol so it is easy communicate with the standard PLC.
1) LCD display
2) , wireless signal output:433MHZ,ZigBee,GPRS,WiFi
3) Easy to install: 3/4 inch NPT thread (pipe thread), or flange mounting
4) Application: Various water treatment (pure water / drinking water / surface water / various water supply / industrial sewage treatment), aquaculture, environmental monitoring, CIP and other industries.
Item | Theory | Description | |
Muti-Parameters sensors | Fluorescence method dissolved oxygen, electromagnetic conductivity | Sensors | Turbidity, pH, ORP, temperature, self-cleaning brush. |
Water-Proof | IP68 | ||
Dissolved Oxygen sensor | Fluorescence method | Range | 0~20mg/L or 0~200% Saturation |
Accuracy | ±0.3mg/L | ||
Resolution | 0.01mg/L | ||
Water-Proof | IP68 | ||
Conductivity Sensor | Electromagnetic method | Range | 1μs/cm~600ms/cm |
Accuracy
| <±1.5%;0~1000 uS/cm: 1uS/cm; 1 mS/cm~600mS/cm: 0.1 mS/cm | ||
Electrode material | PP | ||
Shield material | PPS | ||
Working Temp. | 0~100℃ | ||
Water-Proof | IP68 | ||
Turbidity sensor | Optical fiber | Range: | 0.1~1000NTU |
Accuracy: | <5% or 1NTU | ||
Response time: | <2 sec | ||
Shield material: | 316L | ||
Working Temp: | 0~50℃ | ||
Water-Proof | IP68 | ||
pH sensor | Electrochemistry | Range: | 0-14PH, |
Accuracy: | ±0.01PH, | ||
Resolution: | 0.01PH, | ||
Water-Proof | IP68 | ||
ORP sensor | Electrochemistry | Range: | -1200mV~+1200mV, |
Accuracy: | ±3mV, | ||
Resolution: | 1mV, | ||
Water-Proof | IP68 | ||
Ammonium Nitrogen sensor | Ammonium ion selective electrode method | Range: | NH4-N:1~1000mg/L;NH4+: 1~1290mg/L; NH3-N:0~2.000 mg/L |
Accuracy: | NH4-N ,NH4:±2%F.S. ;NH3-N, NH3:±5%F.S. | ||
Resolution: | NH4-N NH4:1mg/L OR 0.1mg/L ; NH3-N NH3:0.001mg/L | ||
Working Temp.: | 0~50℃ | ||
Water-Proof | IP68 | ||
Concentration sensor | Electromagnetic | Range:
| 0~14% NaOH; 0~15% HCl; 0~15% HNO3; 0~22% NaCl; 0~25% H2SO4. |
Accuracy: | ±2.5%F.S. | ||
Resolution: | 0.01 | ||
Working Temp: | 0~65℃, | ||
Water-Proof | IP68 |