Company Profile |
Section A Gas Gen-set
Genset working condition |
Ambient Temp 0°C~+40°C, Relative Humidity <90%(20°C), Altitude ≤1000m above sea level.
A. Natural gas
1. Adapted Gas: Natural gas,
2. Acceptable Natural gas pipeline pressure: 5~12kPa (before Pressure Regulating Valve.)
3. Gas heat value≥37MJ/Nm3 .
B. Biogas
Acceptable biogas pipeline pressure: 5~12kPa (adjustment required for higher pressure), change ratio≤1kPa/min
CH4 volume content≥30%, adjustment ratio≤2%/min
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3). Genset output power will increase as the gas heat value increase, and if low heat value gas is used (Heat value<5500kcal/Nm3), it could cause power derate.
H2S content≤200mg/Nm3
NH3 content≤20mg/Nm3
Genset Specification
Gas genset data | ||
Genset model | KDGH40-G | |
Prime power (kW/KVA) | 40/50 | |
Continuous Power (KW/KVA) | 32/40 | |
Connection type (V) | 3 Phases 4 Lines | |
Power factor cosfi | 0.8 lagging | |
Frequency (Hz) | 50 | |
Rated speed (RPM) | 1500 | |
Open type Genset Overall Dimension (mm) | 2250x820x1500 | |
Soundproof type Genset Dimension (mm) | 2900x1200x1800 | |
Net weight without canopy(kg) | 1100 | |
Gas Engine Data | ||
Model | HG6B | |
Brand | CAMDA | |
Type | 4 stroke, water-cooling, dry cylinder liner, electronic-control ignition system, pre-mixed perfect mixed burning | |
Cylinders& Arrangement | 6L | |
BoreXStroke(mm) | 102X120 | |
Displacement(L) | 5.88 | |
Compression ratio | 11.5:1 | |
Aspiration | Natural | |
Cooling Method | Radiator fan water cooling | |
Governor type(speed regulating type) | Electronic governing | |
Starting method | Electric, 24 V motor | |
The lowest gas consumption(m3/kw.h) | 0.3 for natural gas/0.6 for biogas |
Section B Optional Equipment
1. Sound-proof canopy
2. CHP system
3. Grid parallel system
4. Remote radiator
5. Auto oil filling system
6. Water heater
7. Oil heater
8. Gas leaking detector
9. Flame detector
10. Gas scrubber
Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com