KH300AG Digital Temperture Pressure Data Logger , Universal Data Logger
Model No.: KH300AG
KH300AG Digital universal data logger, paperless recorder (96*96 mm, up to 6 channels), used the advanced technology, to be designed high quality and performance, isolated, high accuracy, universal use, to be aimed to monitor, record, analysis the processes in various industry application
Used for:
Petroleum, Pharmaceutical, Metallurgy, Paper, Electricity, Chemical, Nuclear power, Cement, Building,Food, aviation, Medical University lab, Marine, Sewage treatment etc variour automation application
Functions | Description | ||||
Power Supply | 100-240 VAC , wide power supply, photoelectric isolated | ||||
Max. Input Channels No. | max. 6 analog input, isolated; | ||||
Analog Input : 0-5VDC, 1-5VDC, 0-10VDC 0-10mA , working with external 500Ω resistor; 4-20mA , working with external 250Ω precise resistor. 0-20mV,0-60mV, 0-100mV Thermocouple Input: K, S, T, E,J, B, N, R, WRE526, WRE325 RTD Input PT100, CU50, CU100 | |||||
Analog Input Range: -20000 to 20000. Thermocouple Input Range: K ( -50 ~ 1300℃ ), S ( -50 ~ 1700℃ ),T ( -200 ~ 350℃ ) ,E ( 0 800℃ ), J ( 0 ~ 1000℃ ), B ( 300 ~ 1800℃ ), N ( 0 ~ 1300℃ ), R(-50-1700℃) , WRE526 (-0 ~ 2300℃), WRE235 (0 ~ 2300℃) RTD Input Range: Cu50 ( -50 ~ 150℃ ) , Pt100 ( -200 ~ 600℃ ), Cu100 ( -50 ~ 150℃ ) | |||||
Accuracy | +-(0.2%FS+1)digit | ||||
Sample Time | 1 S/6 channels | ||||
Data Memory | Big capacity FLASH memory, up to 10 years for long time memory even power off | ||||
Data Save | 8MB built in memory capacity with big capacity | ||||
Data Memory Time | 45days x setting memory interval time / ordered channels no. E.g.: Ordered channels No. :1 , memory interval time setting: 1 second, so it can memory: 45X1/1 =45days data | ||||
Memory Interval Time | 1-3600 seconds, can be seted flexibly | ||||
Up to 8 replay output, 250VAC, 3A relay contact output: NO or NC | |||||
Photoelectrical isolated RS485 communication output | |||||
RS232 printing output for mini printer to printer data | |||||
USB pen drive,TF card port for data transfer | |||||
RS485 Communication | RS485 communication, universal standard MODBUS-RTU protocol; can be configurable with HMI. DCS, MCGS etc directly in market, | ||||
PC software | Display data in digit, curve; also print memorized data in curve; export the data as Excel format for further analysis |