3g /4g module gsm sms power failure alarm, power lost alarm, power recover alarm
Supports 3G WCDMA and 4G LTE Version
1- Remote trun on and turn off relay or switches by phone sms message
2- Connect NO or NC sensors. once sensors triggered, CWT5011 send sms to alert users
3- Can collect data from analog outputs 0-5V or 4-20mA sensors. Send SMS to users once data is abnormal.
Advance features
·Automatically report the status on certain time
·Support remote setting via sms commands
·Preset 10 phone numbers(can be distributed authority)
·Remote add/edit/delete phone group
·Automatically update internal clock via sms
·Time stamped in alarm or recover messages
·Support ring call when alarm
·Temperature sensor (optional)
·Internal battery (optional)
·Easy used GUI configure software
·Adopted highly integrated industrial CPU
·Reliable performance with built-in double watchdog
·Low maintenance, 24×7 operation
2/4/8 digital inputs feature
·NO or NC type can be preset
·Configurable for alarm and recover sms
·Configurable for alarm ensure time
·Configurable for alarm delay time
·Configurable for service number’s authority of receive inputs alarm
·Remote query inputs status
2/4/8 relay drivable outputs
·Multiple output type can be preset
·Remote On/Off/Pulse outputs
·Configurable for pulse time
·Remote query outputs status
·Outputs can be activated by alarm or call
·Outputs can be activated on schedule
CWT5011 GSM SMS alarm control system Program software screenshot:
CWT's SMS Remote Controller CWT5005 CWT5010 CWT5011 can be used as:
A switch with SMS remote control.
A timer-switch which can be activated automatically.
A relay with dialling-in remote control.
An automation system.
A SMS reporter.
A data transporter (GSM DTU, GSM M2M).
A GSM Alarm system.
A GSM Remote Terminals (GSM RTU).
SMS Controller CWT5005 CWT5010 CWT5011 suitable for:
1. Security Alarm System application;
2. Supervision and monitoring alarm;
3. Automatic monitoring system;
4. Vending Machines;
5. Pumping Stations;
6. Buildings and Real Estate;
7. Weather Stations;
8. River Monitoring and Flood Control;
9. Oil and gas pipelines;
10. Corrosion protection;
11. Valve controls;
12. Wellheads;
13. Energy saving, street lights control;
14. Tanks, temperatures, water leakage;
15. Transformer stations;
16. Unmanned machine rooms;
17. Control room application;
18. PLC and Automation, M2M;
19. Access Control, Gate Opener, etc.