5m 3/h промышленный бойлер установка для смягчения воды/Система воды


Поделиться:


Цена:2 300,00 $*

Количество:



Описание и отзывы


Трекер стоимости

Месяц Минимальная цена Макс. стоимость
Sep-17-2025 2737.22 $* 2874.20 $*
Aug-17-2025 2714.61 $* 2850.39 $*
Jul-17-2025 2277.74 $* 2391.2 $*
Jun-17-2025 2668.58 $* 2801.97 $*
May-17-2025 2323.37 $* 2439.93 $*
Apr-17-2025 2622.35 $* 2753.20 $*
Mar-17-2025 2599.30 $* 2729.85 $*
Feb-17-2025 2576.27 $* 2705.46 $*
Jan-17-2025 2553.31 $* 2681.53 $*

Характеристики


5m3/h Industrial Boiler Water Softening Plant/Water Softener System Price/water Softener


 automatic water softener.jpg


 



Product Description


 5m3/h Industrial Boiler Water Softening Plant/Water Softener System Price/water Softener




 


Features/Benefits


Fiberglass reinforced polyester (FRP) pressure vessels for 150 psi working pressure.
High capacity, sulfonated polystyrene cation exchange resin in sodium-form.
Brass, top mounted twin-tank control valve with integral brine injector.
Built-In control valve alternator for continuous soft water supply.
Automatic-reset water meter for volume initiated regeneration.
Self-adjusting flow control to maintain accurate backwash rates.
Internal distribution system for minimal pressure drop and optimal regeneration.
Rigid, polyethylene brine tanks with dry-salt shelf platform and water re-fill valves.


 


Softener
What is Water Hardness
The hardness of any supply water is determined by the contents of calcium and magnesium compounds, which exists to some degree in all natural waters. The hardness in well water is usually higher than that of surface water. Calcium and magnesium can combine with bicarbonates, sulfates, chlorides, and nitrates to precipitate as solids mineral salts make water more basic and corrosion aggressive on many materials.
Hard water is responsible for the formation of lime scaling in pipes, utensils, water heaters, boilers, HVAC systems, etc., causing inefficiency and sometimes permanent damage. Scale acts as an insulation material, thus lowering heat transmission and often causing premature heater failure due to overheating of the metal.


20140424141146_65222.jpg


softener3.jpg


 


softener-3


 


Hard water causes two problems:


Dissolved calcium and magnesium precipitate out of hard water as scale, which builds up on the insides of pipes, water heaters, tea kettles, kettles, coffee makers and industrial machinery. Scale reduces flow through pipes and is a poor conductor of heat. Eventually, pipes can become completely clogged.
Hard water reduces soap's ability to lather, whether in the shower, sink, dishwasher or washing machine, and reacts with soap to form a sticky scum.



working principle


 5m3/h Industrial Boiler Water Softening Plant/Water Softener System Price/water Softener





WATER SOFTENING PROCESS :
Softening is the ion exchange process, it is done through resin, the most common and probably the easiest method of removing hardness (that is calcium and magnesium) from water and suitable for utility purpose. As the name implies ion exchange is a process in which undesirable ions are exchanged for more desirable ions. The softening process consists of passing raw water containing hardness through a bed of cation resin in sodium form. The hardness ions Ca & Mg are taken up by resin and in exchange, the sodium ions are relinquished from the resin. This is called the service cycle, where the hard water is being softened.



CHEMICAL REACTION DURING SOFTENING PROCESS :-
 Ca (HCO3)2 + Na2 R = RCa + NaHCO3
 CaSO4 + Na2 R = RCa + Na2SO4MgCl2 + Na2
 R = RMg + NaCl


 



REGENERATION PROCESS 
 Raw water will continue to get softened till the resin gets exhausted. Bringing back the resin to it original form is called regeneration. Softener resin is regenerated by sodium chloride- Nacl (Common salt) solution. The common salt solution is kept in the regeneration tank. During the regeneration process, salt solution is injected by the ejector tube into softener. The Nacl (salt solution) replaces ca, Mg (Hardness) from the resin, the regeneration is done every day or every few days or every week depending upon the usage and design of the water softener plant.


-12214


 1211


 


 



Application


 5m3/h Industrial Boiler Water Softening Plant/Water Softener System Price/water Softener




Mainly used in industry and civil water softening preparation, such as Boiler feed water make-up water, air conditioning system make up water, heat exchanger, power plant, chemical, textile, printing and dyeing, bio-pharmaceutical, Electronic system and water pretreatment.


 


 


System automatic water softener widely used in steam bioler,heating bioler,exchanger,air conditioner, and other systems water softener,also used in hotel,restruant,office, and other life water treatment and food,drinking,wine,washing,textile,chemical,medicine and other industrial softener water treatment.


 


Water Softening Plants for Boiler feed water
Water Softening Systems for Cooling water make-up
Water Softening Plants for Food and beverages
Water Softening Plants for Hotels and restaurants
Water Softeners for Air conditioning plants
Water Softeners for Laundries



 


Type choice:


Softener equipment applies cation resin for softing raw water,its main target is to use cation resin to adsorp (main parts of ),encreasing the hardness of raw water.


1. Users can choose manual operation control system for saving cost.


2. If users using for 24 hours can accord to water using time choosing for rebirth


3. Uses can according to water quality requirement:first grade multi-media filter,which can remove mud,rust,colloid and suspension in water.Second grade activated carbon filter,which can remove color,olfactory,biochemistry organic in water and encrease the left oxygen value and pollution in water.Third grade equiped softener equipment.


4. Effluent water capacity achieves the water supply of national low-pressure bioler.


5. Time control- type;flow control- type.In working ,apply single-tank,double-tank and multi-tank etc. other varied combination method.When choosing,users can choose as their needs.In operation,it has not only automatic function,but also is manual operation.



Technical Parameters


 5m3/h Industrial Boiler Water Softening Plant/Water Softener System Price/water Softener


Technical parameters


 










































Hardness of


raw water



≤8mmol/L



Power supply



220V/50HZ



Hardness of effluent



≤0.03mmol/L



Control mode



flow rate type, time type



Inlet water pressure



0.2~0.4Mpa



Resin



001×7 strong acidic cation-exchange



Free chlorine



≤0.3mg/L



Working ambient temperature



5-50℃



Suspended solid



<0.5mg/L



System water temperature



5-45℃



Iron content



<0.3mg/L



Relative humidity



≤95%(25℃)



 


 


Specifications:
















































































































































































































Category



Model



Recommended water yield


(M³/h)



Tank size


Diameter *Height(mm)



Salt box


(L)



Amount of resin(KG)



 


 


 


 


 


 


 


Single-valve and single-tank



YL-I-0.5



0.5



200×900



25



20



YL-I-1



1



250×1400



60



40



YL-I-2



2



300×1400



200



60



YL-I-3



3



350×1400



100



80



YL-I-4



4



400×1650



200



120



YL-I-5



5



500×1750



300



180



YL-I-6



6



300×1900



350



240



YL-I-10



8-10



750×1900



500



360



YL-I-18



42-18



900×1900



800



520



YL-I-25



18-25



1000×2200



1000



720



YL-I-35



25-30



1200×2400



1500



1000



YL-I-50



35-50



1500×2500



2000



6400



Dual-valve and dual-tank (simultaneous operation and respective regeneration)



YL-II-36



24-36



900×1900



800



1040



YL-II-50



36-50



1000×2200



1000



1440



YL-II-70



50-70



1200×2400



1500



2000



YL-II-100



70-100



1500×2500



2000



3200



 


 


 


 


 


Dual-valve and dual-tank(One for use and the other for standby)



YL-II-1



1



250×1400



60



80



YL-II-2



2



300×1400



100



120



YL-II-3



3



350×1400



100



160



YL-II-4



4



400×1650



200



240



YL-II-5



5



500×1750



300



360



YL-II-6



6



600×1900



350



480



YL-II-10



8-10



750×1900



500



720



YL-II-18



12-18



900×1900



800



1040



YL-II-25



18-25



1000×2200



1000



1440



YL-II-35



25-35



1200×2400



1500



2000



YL-II-50



35-50



1500×2500



2000



3200



 



Detailed Images


 initpintu_1.jpg




 softening1.jpg


 


 



Packaging & Shipping


5m3/h Industrial Boiler Water Softening Plant/Water Softener System Price/water Softener


Package: wooden cases into container


Delivery: 7-10 working days after deposit received in advance


Shipping methods: FOB Shanghai or by air


QQ20161222091330


-1.jpg 





Our Services


We provide 24 hours online customer service.


Any inquiry about water treatment system, please feel free to contact me for further details!


Contact information:


Mobile phone: +86 15295068302


skype:guo.bei1


Whatsapp: +86 15295068302


Email: lucy AT jsyld.com.cn


Alibaba website: http://js-yilida.en.alibaba.com


Official website: WWW.jsyld.com.cn


 





Company Information


 

22 



Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com