Настенный PTAC PTHP air con с


Поделиться:


Цена:300,00 $*

Количество:



Описание и отзывы


Трекер стоимости

Месяц Минимальная цена Макс. стоимость
Sep-17-2025 357.32 $* 375.84 $*
Aug-17-2025 354.68 $* 372.59 $*
Jul-17-2025 297.2 $* 312.29 $*
Jun-17-2025 348.31 $* 365.18 $*
May-17-2025 303.20 $* 318.60 $*
Apr-17-2025 342.45 $* 359.78 $*
Mar-17-2025 339.80 $* 356.32 $*
Feb-17-2025 336.70 $* 353.91 $*
Jan-17-2025 333.88 $* 350.40 $*

Характеристики


 2014-01-08 03.29.29.jpg


PTAC (PTHP)    PTAC Heat Pump Air Conditioner


 


Worlds Most Efficient Hotel Room Air Conditioner


PTAC (PTHP) Packaged Terminal Air Conditioner Heat Pump


Save 25-40% or more in electricity usage


 


 


RF wireless thermostat:  


Radio Frequency wireless thermostat, 24V wireless controller, easy to install, saves cost as no need the wiring line work, the United States labor expensive, wireless way saves a lot of installation costs. 2019-11-01 12.25.43.png


When it comes to Packaged Terminal Air Conditioners Heat Pump (PTAC/PTHP), you need it all: Quiet, Comfortable, High-efficient and ReliableOur PTAC units deliver on all counts. Whether you're installing PTAC in a new building, or retrofitting units in your existing hospitality, healthcare and other facilities such as hotel rooms, homes, office space. Available in sizes: 7000BTU, 9000BTU, 12000BTU, 15000BTU. Our PTAC units are your smart and economical choice.


 


  2019-11-01 12.25.57.png


 


Container Loading Qty (sets)


20''GP/10''GP/40''HQ : 72/152/190 sets


 


More than 10 years PTAC/PTHP experience, our loading qty is the biggest than other PTAC industry;


Also our PTAC unit is the only one quoted with LCDI power cord and remoter control from factory;


But some other factory all quote and sell LCDI power and cord and remoter control seperately;


So we have price and shipping cost advantage.


 


 2014-01-08 03.38.58.jpg


 


Product Description


   


Specification ( wall through PTAC cooling with electric heater ):


 



























































































































































ModelNPZ-07ENR1NPZ-09ENR1NPZ-12ENR1NPZ-15ENR1
Capacity      
Cooling  capacityBtu/h700090001200015000
EERBtu/w.h11.9211.3510.779.73
Electrical data      
Power supplyV,Ph,Hz208/230,1,60208/230,1,60208/230,1,60208/230,1,60
Power inputkw0.590.791.111.54
Rate currentA2.82/2.553.81/3.455.35/4.847.41/6.70
Electric heater(Optional)kw2/32/32/3/52/3/5
Performance data      
Air flowHigh/LowCFM337/268326/255362/323350/313
Noise levelIndoordB(A)(H/L)49/4849/4850/4950/49
OutdoordB(A)(H/L)59/5859/5860/5960/59
Moisture removalPts./Hr.0.090.711.081.6
Physical data      
Net dimension (W×H×D)In42 x16 x2242 x16 x2242 x16 x2242 x16 x22
Net weight/Gross weightLBS120/130120/130132/142132/142
Loading Qty(20’/40’/40’HQ)Set72/152/19072/152/19072/152/19072/152/190


 


 


Accessories List ( wall through PTAC ):


 2014-01-08 03.44.48.jpg


 


 


 


 


 


Key Features ( wall through PTAC ):


 


1. Langdi blower wheel: Quiet, large volume of wind, good strength, light weight, good balance


      2014-01-08 04.11.12.jpg


Silent design optimized air discharge channel, specialized blower wheel, bigger diameter, lower rotational speed, all contributing better noise control.


 


 


2. A large cross flow fan  ø120*700mm


 


 


3. Plastic sealed motor ensures a quieter and more reliable operation


fan and motor.jpg


 


 


 


4. Optional uiversal electric heater     (3+2) type heater optional 2kw, 3kw, 5kw for customer.


 2014-01-08 04.23.50.jpg


 


 


 


5. The condenser axial fan has three blades which provide for greater air flow. 


 


Additionally we have added a water slinger fan to enhance the condensate management system.


 2014-01-08 03.56.19.jpg


 


 


 


 


6.  Freeze protection and overheating sentinel units can sense and protect against damage caused by freezing ≤ 34°F and overheating danger according to temperature around coil ≥ 149°F.


     Self Diagnostics our units have function of self check error, meanwhile all units can tolerate error internally and automatically restore normally. Also error code will show on electric display.


 


 


7. Easy installation and maintenances  nearly all chassis structure is designed by integral type, whole form air discharge channel, sealed electric PCB box, outdoor sub assembly structure, most parts are under new mould, thus people can install and maintain all the parts easily. Also nylon mesh filters is easy to lift for cleaning.


 


Outdoor sub assembly structure.jpg


 



  • Outdoor sub assembly structure can easily be removed independently for convenient disassembly and cleaning.

  • Indoor air flow sub assembly can be removed as shown, which is ideal for maintenance and cleaning.

  • Integrated structure also ensure blower wheel better position fixing and rotation balance to cut down noise


 


 


8. Fresh air intake with a manual control lever conveniently located on the side of the unit.


 2014-01-08 03.55.16.jpg


When closed only the air inside the room is circulated and filtered,                                                                  ♥ Control lever


When opened outdoor air will be filtered and drawn into the room.


 


 


 


 


9. Compact structure based on maintenance friendly sub assemblies design.


PTAC_packaged_terminal_air_conditioner-6.jpg


 


 


 


 


 


10. The elegance is matched with improved inlet and exhaust air performance


Improved inlet and exhaust air performance-elegance.jpg


 


 


FAQ


 




1. PTAC units Advantages


 


Our PTAC/PTHP heat pump air conditioner is the most efficient PTAC units, saving 25-40% or more in operating power costs while running quieter and lasting much longer than any other PTAC. 


 


 


2. PTAC units are no duct losses, easy to control


 


PTAC units are typically installed in rooms that have an exterior wall, they are also known as through-wall units. It is a self-contained unit that can be installed by a home owner or building maintenance person, since no HVAC license is needed. Because there are no duct losses, an ultra-high efficiency PTAC is less costly to operate than a typical ducted central system. This is not the case however, with all PTACs. Most PTAC units have low efficiency (and high noise levels) similar to that of a window unit. 


 


Because a PTAC is used on a room-by-room basis, you only use the amount of energy that is needed for that room, at that time. Optional occupancy sensors can make sure the unit is only running when people are present, and all PTAC units can be controlled from a central location such as a front desk or building automation system. 


 