Instrumentation And Control Blood Warmer



Product Description

 








  TECHNICAL DATA

 


 

















































































Name blood warmer heater
Power supply

100 - 240VAC/50-60 Hz


Power consumption

1.5A/115 VAC       1.0A/230VAC


Fuse

2×T2.5A/250V


Type of protection against electric shock

Class I



Degree of protection against electric shock



BF Applied part; Defibrillation-protected



Degree of protection against ingress of liquids



IPX2



Temperature setting



33°C ~ 41°C (91~106℉) ( 0.1°C increments) (1℉)



Accuracy



±1.0°C (±2.0℉)



Overheat switch off



42 ±1°C/43±2°C (108±2℉/110±4℉)



Low temperature alarm



32±1°C (89±2℉)



Warming up time



Less than 2 minutes (23±2°C ~36°C) (73±4℉~97℉)



Operating mode



Continuous



MDD Classification



IIb according to rule 9



Dimensions: (L×W×H)



184×148×110mm



Warming profile



WP-143505, length 1.4 m, for infusion tube Æ3.5-5mm(O.D.)



(Refer to the label on device)



WP-146505, length 1.4 m, for infusion tube Æ6-7mm(O.D.)



Heating power



60W



Weight



1.2kg





 


Detailed Images

 


 








  Appearance and Control Panel

  








  Fig.1:General illustration

 


undefined  








  Fig.2:Illustration of LED screen

 


undefined








  Fig.3:Illustation of the control panel

 


undefined



  • The device can be fixed to the infusion stand or other support by using the clamp at the back.

  • Only use infusion stands or supports which be capable of supporting a minimum of ten pounds (4.5 kg) and with a minimum 60cm diameter wheelbase.

  • Make sure that they are sufficiently stable to against tipping over.


Warning:


After the device be fixed stable, it cannot be pull or application of   force   any   way   to   avoid   the   infusion   stands   or   supports   tipping   over.   Failure   to   do   so   may   result in damage to the device, the device may drop down with the infusion line   and   prevent or interrupt the infusion   flow.


 








  INSTALLATION AND OPERATION PROCEDURE

 


Installation:



  • Check whether the device is damaged. Please do not use it if any damage has   been   found.

  • Fix the device firmly to the infusion stand at the position of 20-30cm below   the   infusion/blood bag, using the clamp at the back, then screw the fastening screw.   The   device is almost equal to the drip   bucket.

  • Only use infusion stands or poles that are sufficiently   stable.

  • Before connecting to mains power supply, check the voltage specified on the   device   label.

  • Connect power cable to power supply. The display lights on and beeps. The device   is   in STANDBY   mode.


Warning:


Do not locate the device at the position where it is difficult to be disconnected   from


the mains   power.


undefined








Fig.4:Illustration of the fastening clamp

 


 


Operation   procedure



  • Glide the roll clamp next to the drip bucket or at the end of the infusion   tubing.

  • Empty the air in tubing to make infusion channel   ready.

  • Take the primed infusion line at 2-3cm to the end of patient side to insert in the tail   (small   end) of the warming profile. Afterwards move your thumb over the infusion line and   press   the line gently into the groove towards the head (big end) of the warming profile, until   the   infusion line is completely wrapped in the warming   profile.

  • Place the ends of the warming profile into the holder to prevent the infusion   tube   contacting with the   ground.

  • Press the key or the key to select the desired   temperature.

  • Adjust  the appropriate infusion rate.   As   soon as infusion   is   started, press the key   to   start   warming .

  • Resetting of temperature can only be performed in Standby   mode.

  • If the  infusion needs to   be   stopped for  more than 3  minutes,  press the     key to   stop   warming. By press the key again to resume   it.


Warning: The warming profile must not be placed directly on patient's skin   to   prevent scald by build-up   heat. undefined  








Fig.5:Illustration of the holder of warming profile

 


Shutting down the device



  • Press the key  to enter STANDBY  mode.

  • Release all pressure in the infusion system by switching off the pressure cuffs or   infusion pumps.

  • Remove the consumable material from the warming profile and dispose it according to   the relevant  regulations.

  • Disconnect the device from the power supply. Clean and disinfect the equipment  according to  instructions.


Warning: If the over- temperature alarm is triggered or any suspected malfunction be   perceived   while in operation, the supply of liquid to the patient must be immediately  stopped. Lock the connection tube to the patient, release all pressure in the infusion system   by   switching off the pressure cuffs or infusion pumps. Switch the device off or pull   the   mains plug out. The medium being used in the device must  no   longer   be   administered to the   patient. Wait about 5 minutes until the warming profile has cooled down. Switch the  device   on again. If the fault occurs again, the device must be inspected by a trained   service   technician.




 


Certification

 


undefined   
CE certification  provides a unified technical specification for the trade of our blood warmer heater. CE Certification  indicates that our product blood warmer heater has reached the safety requirements specified in the European Union directive.


 free international sales license is not only the highest level of the United States  certification, and WTO (WTO) approved the highest pass certification about food and drug, only required by the  and the world trade organization fully approved only after the payment of the certificate.


In the United States, Canada and Europe, ISO 13485  is widely used as a quality assurance system, and the establishment of medical equipment quality assurance system is based on these standards. The products blood warmer heater of our company are not only listed on the international market.




 


Application

 


undefined
undefined

 




 


  


Our Company


undefined  


1. We are specializing in the production of  blood warmer heater ,  first aid kits, military bags, and their configurations are on our series.


2.Our advantages: Customized  service , printed logo, full-color types ,good price with high quality,delivery on time,durable and so on.


3. We have a professional 24-hour customer service professional. if you have any question about our blood warmer heater ,you can ask anytime.




 


Our Service

 


01.OEM Service : Dear customer ,we are factories which can do OEM business,please provide your samples you may need to make or dressing samples,the LOGO or any spectifications adout the products,we will try our best to make dream product you want.
02.Sample Service: We could offer the sample for free charge,but do not pay the cost of freight.