Поделиться:
Месяц | Минимальная цена | Макс. стоимость |
---|---|---|
Sep-18-2025 | 0.77 $* | 0.71 $* |
Aug-18-2025 | 0.72 $* | 0.20 $* |
Jul-18-2025 | 0.63 $* | 0.27 $* |
Jun-18-2025 | 0.18 $* | 0.76 $* |
May-18-2025 | 0.93 $* | 0.71 $* |
Apr-18-2025 | 0.72 $* | 0.34 $* |
Mar-18-2025 | 0.73 $* | 0.94 $* |
Feb-18-2025 | 0.20 $* | 0.5 $* |
Jan-18-2025 | 0.79 $* | 0.8 $* |
Flat / Round PVC / Rubber electric submersible pump wire cable 4 core / 3 core for irrigation and deep well **L** --Item No: RVVB4
Technical data Cable structure Application
- Three Core Cable for Submersible - Plain Copper conductor extra fine - PVC insulated & sheathed
Pumpsets with PVC Insulation as per stranded & bunched in accordance flexible Three Core Flat cables
Type A of IS 5831/1984 & Sheathing to IS 8130/1984 for higher flexibility. are used to connect underwater
as per ST I Type of IS 5831/1984. - Each of the cores are insulated with Submersible Pumpsets with
- Conductor resistance PVC Compound for better insulation supply line.
In accordance to IS: 8130/84. resistance against water and moisture. - Agriculture, Irrigation,
- Conductor resistance factor - Cores are laid in flat parallel manner Domestic Installation, Outdoor
at +20 C – see technical information and sheathed for highest performance application & Power Supply.
- Admissible working temperature in severe & difficult conditions. -The outer sheath of the cable
- At the conductor - Marking of brand name, cross-section being made of special grade
PVC Type A & ST 1 +70C ISI License No. & Logo on each mtr. Abrasion resistant PVC makes it
H.R. Grade ST 2 + 90C - Testing of cable carried out as per impervious to water, grease, oil,
- Working voltage upto 1100 V IS 694/90 at our In House facility. etc making cables highly durable
CABLE DESIGN:A submersible Pump cable is a specialized product to be used for submersible pumps in a deep well. The area of installation is physically restrictive, and the environment is very hostile. This cable is designed and manufactured keeping in mind these factors to achieve the highest possible degree of reliability.
FEATURE :
Quality backed by 40 years experience in cable industry.
Excellent resistant to moisture, abrasion, grace, oil.
Longer Flex Life
Excellent mechanical & electrical properties.
Generally Conforming to : CENELEC HD 21, IEC 60227,
BS 6500, DIN VDE 0281, IS 694.
APPLICATION :
For continuous use in deep well to supply power to submersible pumps
Technical data
- Three Core Cable for Submersible Pumpsets with PVC or Rubber Insulation as per Type A of IS 5831/1984 & Sheathing as per ST I Type of IS 5831/1984.
-Conductor resistance In accordance to IS: 8130/84.
-Conductor resistance factor at +20C – see technical information
-Admissible working temperature
-At the conductor Rubber or PVC Type A & ST 1 +70C
H.R. Grade ST 2 + 90C
-Working voltage upto 1100 V
Cable structure
Plain Copper conductor extra fine stranded & bunched in accordance to IS 8130/1984 for higher flexibility.
Each of the cores are insulated with rubber PVC Compound for better insulation resistance against water and moisture.
Cores are laid in flat parallel manner and sheathed for highest performance in severe & difficult conditions.
Marking of brand name, cross-section ISI License No. & Logo on each mtr.
-Testing of cable carried out as per IS 694/90 at our In House facility.
Application
-rubberr or PVC insulated & sheathed flexible Three Core Flat cables are used to connect underwater Submersible Pumpsets with supply line.
-Agriculture, Irrigation, Domestic Installation, Outdoor application & Power Supply.
-The outer sheath of the cable being made of special grade Abrasion resistant PVC makes it impervious to water, grease, oil, etc making cables highly durabl
4CORE FLAT CABLES FOR SUBMERSIBLE PUMPS (1100 VOLTS) | ||||||||
CONDUCTOR | INSULATION | SHEATH | Conductor Resistance at 20°C (max) ohms/km | CURRENT | ||||
Nominal | Nos. & Dia. | Nominal | Nominal | Nominal | Approx. Overall | Rating at 40°C | ||
Area in | of wire | Thickness | Core Dia. | Thickness | Dimensions | Amps. | ||
Sq. mm. | Nos. / mm | mm | mm | mm | Thickness | Width | ||
mm | mm | |||||||
1.5 | 22/0.30 | 0.8 | 3.25 | 1.3 | 6 | 15.8 | 12.1 | 14 |
2.5 | 36/0.30 | 0.9 | 3.84 | 1.3 | 6.5 | 18 | 7.41 | 18 |
4 | 56/0.30 | 1 | 4.5 | 1.45 | 7.6 | 21 | 4.95 | 26 |
6 | 85/0.30 | 1 | 5.3 | 1.5 | 7.9 | 24.3 | 3.3 | 31 |
10 | 140/0.30 | 1 | 6.5 | 1.8 | 9.9 | 29.7 | 1.91 | 42 |
16 | 226/0.30 | 1 | 8 | 1.95 | 11.8 | 36 | 1.21 | 57 |
25 | 354/0.30 | 1.2 | 10.1 | 2 | 14.7 | 45.1 | 0.78 | 72 |
35 | 495/0.30 | 1.2 | 11.5 | 2 | 16.2 | 50.1 | 0.554 | 90 |
50 | 703/0.30 | 1.4 | 13.6 | 2.2 | 18.3 | 58.1 | 0.386 | 115 |
70 | 440/0.45 | 1.4 | 15.3 | 2.2 | 20 | 66.5 | 0.272 | 143 |
95 | 475/0.50 | 1.6 | 18 | 2.4 | 23.5 | 77.3 | 0.206 | 165 |
Note :
Safety Requirements
1. Coiled Submersible cable must always be spread out before using to avoid overheating in use.
2. Ensure proper joining of the cable in order to avoid failure and short circuit.
3. Proper care should be taken while inserting the cable in the borewell to avoid slicing of the sheathing.
4. Kindly ensure proper storage of the cables in order to avoid physical damage.
4. Cables with damaged insulation must be replaced immediately.
Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com