Copper Certifications | ||
Category 6A / Class EA Test Time | 8 Seconds | |
Category 8 / Class I/II Test Time | 15 Seconds | |
HDTDX/HDTDR Diagnostic Test Times | ~3 Seconds | |
Internal Memory | ~5,000 Cat 8 with plots ~12,000 Cat 6A with plots | |
Level V Accuracy | 1 GHz | |
2G Accuracy | 2 GHz | |
Resistance Unbalance Measurement | Yes | |
Shield Integrity Check | Yes | |
TCL Measurement | Yes | |
ELTCTL Measurement | Yes | |
CDNEXT Measurement | Yes | |
CMRL Measurement | Yes | |
Built in Alien XTalk Module | Yes | |
Channel Adapter | 2 GHz Range | |
Permanent Link Adapter | 2 GHz Range | |
Environmental | ||
Operating Temperature | 32°F to 113°F (0°C to 45°C) | |
Storage Temperature | -22°F to 140°F (-30°C to 60°C) | |
Operating Relative Humidity (% RH Without Condensation) | 0% to 90%, 32°F to 95°F (0°C to 35°C) 0% to 70%, 95°F to 113°F (35°C to 45°C) | |
Vibration | Random, 2 g, 5 Hz-500 Hz | |
Shock | 1 m drop test with and without module and adapter | |
Safety | CSA 22.2 No. 61010, IEC 61010-1 3rd Edition | |
Operating Altitude | 13,123 ft (4,000 m) 10,500 ft (3,200 m) with AC Adapter | |
EMC | EN 61326-1 | |
General Specifications | ||
Autotest Time | Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds | |
Support Test Parameters | Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-to-crosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F) | |
Input Protection | Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage | |
Display | 5.7 in LCD display with a projected capacitance touchscreen | |
Case | High impact plastic with show absorbing overmold | |
Dimensions | Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm) | |
Weight | Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg) | |
Main Unit and Remote | Lithium ion battery pack, 7.2 V | |
Typical Battery Life | 8 hours | |
Charge time | Tester off: 4 hours to charge from 10 % capacity to 90 % capacity | |
Languages Supported | English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Traditional Chinese, Czech, Polish, Swedish, Hungarian | |
Calibration | Service center calibration period is 1 year |