Model | CHCI-3.6K-5.12kWh | CHCI-3.6K-10.24kWh | CHCI-5.0K-5.12kWh | CHCI-5.0K-10.24kWh | CHCI-6.0K-5.12kWh | CHCI-6.0K-10.24kWh | ||||||
PV Input | ||||||||||||
Absolute max Voltage (V) | 600 | |||||||||||
MPPT Voltage Range (V) | 100-550 | |||||||||||
Max. DC Input Power (W) | 4800 | 6650 | 8000 | |||||||||
Start-up Voltage (V) | 90 | |||||||||||
Rated Operating Voltage (V | 360 | |||||||||||
Max. Input Current (A) | 12.5/12.5 | |||||||||||
Isc PV (A) | 18/18 | |||||||||||
NO. of MPP Trackers | 2 | |||||||||||
NO. of Strings per MPP Tracker | ||||||||||||
Battery | ||||||||||||
Battery Capacity | LiFeP04 5.12kWh/10.24kWh | |||||||||||
Nominal Battery Voltage (V) | 204.8/409.6 | |||||||||||
Battery Voltage Range (V) | 160...227.2/320...454.4 | |||||||||||
Max. Charge/Discharge Current (A) | 25/25 | |||||||||||
AC Input/Output | ||||||||||||
Max. Apparent Power to Grid (VA) | 3600 | 5000 | 6000 | |||||||||
Rated Power (W) | 3600 | 5000 | 6000 | |||||||||
Max. Apparent Power from Grid (VA) | 7200 | 10000 | 12000 | |||||||||
Rated Voltage (V) | 220/230/240 | |||||||||||
Rated Frequency (Hz) | 50/60 | |||||||||||
Rated AC Current to Grid (A) | 15.6 | 21.7 | 26.1 | |||||||||
Rated AC Current from Grid (A) | 31.2 | 43.4 | 52.2 | |||||||||
Rated AC Current from Grid (A) | 31.2 | 43.4 | 52.2 | |||||||||
Displacement Power Factor | 1(-0.8…+0.8 adjustable) | |||||||||||
THDi | <3% | |||||||||||
EPS Output (With Battery) | ||||||||||||
Max. Output Power (W) | 3600 | 5000 | 6000 | |||||||||
Rated Apparent Power (VA) | 4320 | 6000 | 7200 | |||||||||
Rated Voltage (V) | 230(±2%) | |||||||||||
Norminal Frequency (Hz) | 50/60(±0.2%) | |||||||||||
Rated Output Current (a.c.A) | 18.8 | 26.1 | 31.3 | |||||||||
Switch time (ms) | <10 | |||||||||||
THDv @Linear Load (%) | <2 | |||||||||||
Efficiency | ||||||||||||
PV Max Eficiency (%) | 97.6 | |||||||||||
PV Europe Efficiency (%) | 97 | |||||||||||
PV Max. MPPT Efficiency (%) | 99.9 | |||||||||||
Battery Discharge Efficiency (%) | 96.7 |