Project index | Parameter index | ||
Input Power | AC 220V ±10% / 50Hz | ||
resolution | AD:16bit;DA:16bit | ||
Input Resistance | ≥1MΩ | ||
Input Power | 425W | ||
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | ||
Channel Control Mode | Independent Control | ||
Per Channel Voltage Range | Charge:10mV~5V;Discharge:10mV~5V | ||
Discharge Min Voltage | 2.5V | ||
Accuracy | ± 0.05% of FS | ||
Stability | ± 0.05% of FS | ||
Per Channel Current Range | Range 1: 0.0001A-0.1A, Range 2: 0.1A-6A | ||
Accuracy | ± 0.05% of FS | ||
Stability | ± 0.05% of FS | ||
Per Channel Output Power | 30W | ||
Stability | ± 0.1% of FS | ||
Time | Current Response Time | 1ms (0-Full Range) | |
Step Time Range | ≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) | ||
Data Recording | Record Condition | Minimum Time Interval: 100ms | |
Minimum Voltage Interval: 10mV | |||
Minimum Current Interval : 12mA | |||
Record Frequency | 10Hz | ||
Charge Mode | Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,CPC | ||
End Condition | Voltage,Current,Relative Time,Capacity | ||
Discharge | Discharge Mode | CCD,CPD,CRD | |
End Condition | Voltage,Current,Relative Time,Capacity, | ||
charge | CCC | ||
Discharge | CCD | ||
Min Pulse Width | 500ms | ||
Automated Switch | Automated swith from charge to discharge for each pulse | ||
End Condition | Voltage, Test Time | ||
Loop Measure Range | 1~65535 times | ||
Max Steps Per Loop | 254 | ||
Nested Loop | Nested loop Function,Max Support 3 Layers | ||
Protection | Software Protection | l Power-down Data Protection | |
l Off-line Testing Function | |||
l Setting Protection Condition,Setting Parameter: Low Voltage limit,Upper Voltage limit,Low Current limit, Upper Current limit,Delay Time | |||
Hardware Protection | Additional Anti-reverse Protection Model | ||
Voltage and Current Testing Sample | 4-wire connecting | ||
Noise | <85dB | ||
Database | MySQL Database | ||
A Means of Communication of Upper Machine | TCP/IP Protocol | ||
Data Output | EXCEL,TXT,Graph | ||
Communication Interface | Ethernet Port | ||
Per Unit Main Channels No. | 8 | ||
Dimensions | 3U,482*508*378(mm) |