Поделиться:
Месяц | Минимальная цена | Макс. стоимость |
---|---|---|
Sep-19-2025 | 5595.17 $* | 5875.58 $* |
Aug-19-2025 | 5548.55 $* | 5825.16 $* |
Jul-19-2025 | 4655.55 $* | 4888.28 $* |
Jun-19-2025 | 5454.62 $* | 5727.54 $* |
May-19-2025 | 4749.2 $* | 4986.22 $* |
Apr-19-2025 | 5360.97 $* | 5628.21 $* |
Mar-19-2025 | 5313.75 $* | 5579.40 $* |
Feb-19-2025 | 5266.57 $* | 5529.50 $* |
Jan-19-2025 | 5219.44 $* | 5480.93 $* |
Model | BNMS-N100 |
Wavelength Range | 200-800nm |
Minimum Sample Volume | 0.5-2.0μl |
Light Path | 0.2mm |
1.0mm | |
Light Source | Xenon flash lamp |
Detector Type | 3864-Linear CCD array |
Wavelength Accuracy | 1nm |
Wavelength Resolution | ≤3nm (FWHM at Hg546nm) |
Absorbance Precision | 0.003Abs |
Absorbance Accuracy | 1% (7.332Abs at 260nm) |
Absorbance Range | 0.02 - 90A |
Nucleic Acid Measurement Range | 2-4500ng/ul (dsDNA) |
Measurement Time | <8S |
Output Interface | Connect PC |
Sample Pedestal Materia | Aluminum alloy and Quartz fiber |
Operating Voltage | 24V DC |
Operating Power | 20W |
Standby Power | 5W |
Dimension (W x D x H) | 200 x 250 x 166mm |
Weight | 2.6kg |
Software Compatibility | WinXP,Win7,Win8 |
Model | BNMS-N200 | |
Wavelength Range | 200-800nm | |
Minimum Sample Volume | 0.5-2.0μl | |
Light Path | 0.2mm | |
1.0mm | ||
Light Source | Xenon flash lamp | |
Detector Type | 2048-Linear CCD array | |
Wavelength Accuracy | 1nm | |
Wavelength Resolution | ≤3nm (FWHM at Hg546nm) | |
Absorbance Precision | 0.003Abs | |
Absorbance Accuracy | 1% (7.332Abs at 260nm) | |
Absorbance Range | 0.02 - 100A | |
Nucleic Acid Measurement Range | 2-5000ng/ul (dsDNA) | |
Measurement Time | <5S | |
Output Interface | USB | |
Sample Pedestal Materia | Aluminum alloy and Quartz fiber | |
Operating Voltage | 24V DC | |
Operating Power | 25W | |
Standby Power | 5W | |
Dimension (W x D x H) | 210 x 268×181mm | |
Weight | 2.8kg | |
Operating System | Android | |
OD600nm Measurement | ||
Light Source | LED | |
Wavelength Range | 600±8nm | |
Absorbance Range | 0-4Abs |
Model | BNMS-N300 |
Wavelength Range | 190-850nm |
Minimum Sample Volume | 0.3-2.0μl |
Light Path | 1.0mm |
Light Source | Xenon flash lamp |
Detector Type | 3864-Linear CCD array |
Wavelength Accuracy | ±1nm |
Wavelength Resolution | ≤2nm (FWHM at Hg546nm) |
Wavelength Repeatabbility | ±0.5nm |
Absorbance Precision | 0.002Abs |
Absorbance Accuracy | 1% (0.76Abs at 350nm) |
Absorbance Range | 0.002 - 15A (equivalent to 10mm optical path) |
Nucleic Acid Measurement Range | 2-750ng/ul (dsDNA) |
Detects Protein Measurement Range | 0.1-40mg/ml (BSA) |
Measurement Time | <5S |
Output Interface | 2×USB |
Sample Pedestal Materia | Stainless steel and Quartz fiber |
Display | 7 inch touch screen |
Operating Voltage | 12V DC |
Dimension (W x D x H) | 200 x 300×200mm |
Weight | 2.8kg |
Operating System | Win10 |
Cuvette model Measurement | N/A |
Model | BNMS-N400 | BNMS-N410 | ||
Wavelength Range | 190-850nm | 190-850nm | ||
Minimum Sample Volume | 0.3-2.0μl | 0.3-2.0μl | ||
Light Path | 0.05mm | 0.05mm | ||
0.5mm | 0.5mm | |||
1.0mm | 1.0mm | |||
Light Source | Xenon flash lamp | Xenon flash lamp | ||
Detector Type | 3864-Linear CCD array | 3864-Linear CCD array | ||
Wavelength Accuracy | ±1nm | ±1nm | ||
Wavelength Resolution | ≤2nm (FWHM at Hg546nm) | ≤2nm (FWHM at Hg546nm) | ||
Wavelength Repeatabbility | ±0.5nm | ±0.5nm | ||
Absorbance Precision | 0.002Abs | 0.002Abs | ||
Absorbance Accuracy | 1% (0.76Abs at 350nm) | 1% (0.76Abs at 350nm) | ||
Absorbance Range | 0.002 - 300A (equivalent to 10mm optical path) | 0.002 - 300A (equivalent to 10mm optical path) | ||
Nucleic Acid Measurement Range | 2-15000ng/ul (dsDNA) | 2-15000ng/ul (dsDNA) | ||
Detects Protein Measurement Range | 0.01-400mg/ml (BSA) | 0.01-400mg/ml (BSA) | ||
Measurement Time | <5S | <5S | ||
Output Interface | 2×USB | 2×USB | ||
Sample Pedestal Materia | Stainless steel and Quartz fiber | Stainless steel and Quartz fiber | ||
Display | 7 inch touch screen | 7 inch touch screen | ||
Operating Voltage | 12V DC | 12V DC | ||
Dimension (W x D x H) | 200 x 300×200mm | 200 x 300×200mm | ||
Weight | 3.5kg | 3.5kg | ||
Operating System | Win10 | Win10 | ||
Cuvette model Measurement | ||||
Optical Path of Cuvette | N/A | 1mm,2mm,5mm,10mm | ||
Temperature Range | N/A | N/A | ||
Minimum Sample Volume of Cuvette | N/A | 50ul | ||
Minimum height of sample in cuvette | N/A | 5mm |