1. Power supply AC220-240V, 50Hz;
2. Power on, heating and fan rotation, working for 12 hours by default without pressing any button;
3. Press the time button to switch to the timing setting. "Old = press" +- "to set the timing time; New = press the time button to
set the time" and then press the time button to switch back to the temperature setting;
4. The initial display temperature is 20 degrees Celsius. Press the up and down button to set the temperature, and the range is
15~32 degrees Celsius.Under the time setting, the timing is set for 1~12 hours;
5. Press the fan button to switch between high (HH) and low (LL) fan speeds;
6, Reached the set temperature, cut off the heating, the fan continues to work for 60 seconds after the stop, the screen shows OF,
below the set temperature -1, reheat;
7. When the timing time is reached (if not set, the default time is 12 hours), cut off the heating, and the fan will continue to
work for 60 seconds and then stop, and the screen will display OF;
8. After finishing the work, press any key to start the work again (12 hours is the default if no time is set)
9. If "natural wind" function is available, press and hold "+-" button for three seconds to start, and CC will be displayed;
Continue to press and hold "+-" button for three seconds to close, display "natural wind" before starting the setting