Поделиться:
Месяц | Минимальная цена | Макс. стоимость |
---|---|---|
Sep-19-2025 | 0.80 $* | 0.96 $* |
Aug-19-2025 | 0.43 $* | 0.20 $* |
Jul-19-2025 | 0.68 $* | 0.31 $* |
Jun-19-2025 | 0.16 $* | 0.31 $* |
May-19-2025 | 0.78 $* | 0.8 $* |
Apr-19-2025 | 0.92 $* | 0.85 $* |
Mar-19-2025 | 0.20 $* | 0.92 $* |
Feb-19-2025 | 0.32 $* | 0.64 $* |
Jan-19-2025 | 0.99 $* | 0.97 $* |
ØUnique AutoPure is a flexible and intuitive chromatography system for the purification of microgram to gram levels of proteins, peptides, nucleic acids, polysaccharides and other target substances.
ØUnique CDSystem chromatography workstation is a powerful, advanced and highly stable chromatography data management system that integrates instrument control, method management, data analysis, standard curve, report editing, user rights management, audit trail, digital signature, Network database and other functions.
ØUnique AutoPure selects the core components of well-known European and American manufacturers, with stable performance and high precision; the components in contact with the sample are all biologically inert materials with good biological compatibility.
configuration options | product name | technical parameter | |||
The standard configuration | Unique AutopureInfusion Pump | Unique Autopure25 | Unique Autopure100 | Unique Autopure150 | Unique Autopure300 |
double pump system,Flow rate range: 0.001-25ml/min;Pressure range; 0-27.5MPa (4000psi)Flow accuracy: ±1.2%; | pump system,Flow rate range: 0.001-100ml/min;Pressure range: 0-10MPa(1500psi);Flow accuracy: ±1.2%; | double pump system,Flow rate range: 0.001-150ml/min;Pressure range: 0-5MPa (725psi);Flow accuracy: ±1.2%; | double spring system,Flow rate range: 0.01-300ml/min;Pressure range; 0-3.5MPa (500psiFlow accuracy: ±2%; | ||
Flow rate repeatability: RSD≤0.5%;Gradient type: linear, isocratic, step gradient, the gradient ratio can be modified online; | |||||
Autosampler valve module | Three-position seven-port valve, software reverse control, support quantitative injection; support Load, Inject, Waste functions; | ||||
Fixed single wavelength detector module | LED light source, fixed single wavelength, service life ≥ 8000 hours;Detection wavelength 280nm, 260nm or 254nm optional;Wavelength accuracy ±1nm, wavelength repeatability ±0.5nm;Drift: 1*10-3AU/Hr;Noise: 4*10-5AU(@254nm,1S); | ||||
temperature sensor module | Reading range: O-100°C, accuracy ±1%, temperature compensation for conductance and pH; | ||||
Conductivity Detector Module | Detection range: 0-999.999mS/cm, accuracy ±2%, detection cell volume 20ul; temperature compensation included; | ||||
Back pressure valve module | 20-200psi adjustable, biocompatible | ||||
In-Line Filter Module | 20um titanium alloy filter | ||||
Dynamic Mixer Module | 2ml mixing chamber | ||||
Chromatography column clamp | two | ||||
starter pack | Start-up package (including pipes, connectors, maintenance tools, manuals, dongle, etc.); | ||||
Control System | Control system (including brand computer, keyboard, mouse, Chinese and English operating software)24 hours of uninterrupted operation; | ||||
select configuration | pH Detector Module | Detection range pHO-14, accuracy ±0.1; flow cell dead volume 76ul; temperature compensation included; | |||
Bubble Sensor Module | Used to monitor sample loading and monitor the generation of air bubbles in the system; | ||||
Buffer inlet valve module | Four channels, including A pump A1-A2, B pump B1-B2;Eleven channels, including A pump A1-A9, B pump B1-B2;Eighteen channels, including A pump A1-A9, B pump B1-B9; | ||||
UV detector module | L2 fixed dual wavelength, detection range 280nm and 260nm (or 200-600nm optional two fixed wavelengths); | ||||
DAD402 variable dual wavelength, detection range 200-400nm, full spectrum direct reading, can detect two arbitrary wavelengths at the same time; | |||||
DAD604 variable four wavelengths, detection range 200-600nm, full spectrum direct reading, can detect four arbitrary wavelengths at the same time; | |||||
DAD804 full wavelength detection, detection range 200-800nm, full spectrum direct reading, can detect four arbitrary wavelengths at the same time; | |||||
Outlet valve module | 2 channels, 1 channel for large volume sample collection, 1 channel for waste liquid outlet; | ||||
Nine channels, 8 channels for large volume sample collection, 1 channel for waste liquid outlet; | |||||
Fraction collector module | Frac-01 supports 1-50m sample collection, and comes standard with a collection rack (96-well plate or centrifuge tubes and test tubes of different specifications can be selected); | ||||
Frac-02 supports 1-50ml sample collection, and comes standard with two collection racks (96-well plates or centrifuge tubes and test tubes of different specifications can be selected); | |||||
Frac-02P supports 1-50ml sample collection, and comes standard with two collection racks (96-well plates or centrifuge tubes and test tubes of different specifications can be selected); | |||||
Frac-02C supports 1-50m sample collection, and comes standard with two collection racks (96-well plates or centrifuge tubes and test tubes of different specifications can be selected); | |||||
Column valve module | Single column valve, support forward/reverse/BypassS; | ||||
Three-column valve, can connect three chromatography columns and BypaSS at the same time, each column supports forward flushing and backflushing; | |||||
Pressure Monitoring Module | Pre-column pressure monitoring | ||||
Pre-column and post-column pressure monitoring | |||||
Sample Pump Module | SP25, the flow rate range is 0.001-25ml/min, the pressure range is 0-27.5MPa. The flow rate accuracy is ±1.2%; | ||||
SP100, the flow rate range is 0.001-100ml/min, the pressure range is 0-10MPa, and the flow rate accuracy is ±1.2%; | |||||
SP150, the flow rate range is 0.001-150ml/min. The pressure range is 0-5MPa. The flow rate accuracy is ±1.2%; | |||||
SP300, the flow rate range is 0.01-300ml/min, the pressure range is 0-3.5MPa, and the flow rate accuracy is ±2%; | |||||
Sample Inlet Valve Module | Two channels, 1 sample inlet. 1 buffer inlet; | ||||
Nine channels. 8 sample inlets. 1 buffer inlet: |
1. This is a configurable system, please contact us for detailed configuration and quotation if you are interested.
Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com