Тип B RCCB 2 полюса 4 40 А 63 а постоянный ток утечки земли 10 ка 300 мА RCD


Поделиться:


Цена:80,00 $ - 118,00 $*

Количество:



Описание и отзывы


Трекер стоимости

Месяц Минимальная цена Макс. стоимость
Sep-17-2025 95.48 $* 100.60 $*
Aug-17-2025 94.31 $* 99.2 $*
Jul-17-2025 79.96 $* 83.96 $*
Jun-17-2025 93.45 $* 98.2 $*
May-17-2025 81.68 $* 85.34 $*
Apr-17-2025 91.38 $* 96.46 $*
Mar-17-2025 90.52 $* 95.50 $*
Feb-17-2025 90.96 $* 95.42 $*
Jan-17-2025 89.83 $* 93.2 $*

Характеристики


 

 


Product Description


 


40A 63A 80A 100A 30mA 4Pole Type B RCD RCCB Residual Current Circuit Breaker


Type B RCCBs, in addition to normal AC, can detect high frequency AC and pure DC earth leakage currents. Reducing the risk of fire and/or electrocution through automatic disconnection of the electrical supply relies on the selection of the correct type of RCCB EKL1-63B








 


 


.


 



Features


 


 



Electrical Features





































































ModelHENGYI-80B
Type(wave form of the earth leakage sensed)B Type RCCB
Rated current In40A,63A, 80A,100A
Poles2Pole and 4Pole
Rated voltage Ue2Pole: 230V / 240V , 4Pole: 400V / 415V
Insulation voltage Ui500V
Rated frequency50/60Hz
Rated residual operation current(I n)30mA,100mA,300mA
Rated residual making and breaking capacity (I m)500(In=2540A) 630(In=63A)
Short-circuit current Inc= I c10000A
SCPD fuse10000
Break time under I n≤0.1s
Rated impulse withstand voltage(1.5/50) Uimp4000V
Dielectric test voltage at ind.Freq. for 1min2.5kV
Electrical life2,000 Cycles
Mechanical life4,000 Cycles

Installation













































Contact position indicatorYes
Protection degreeIP20
Ambient temperature(with daily average≤35°C)-5°C~+40°C
Storage temperature-25°C~+70°C
Terminal connection typeCable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable25mm2 18-3AWG
Terminal size top/bottom for busbar25mm2 18-3AWG
Tightening torque2.5Nm 22In-lbs
MountingOn DIN rail EN60715(35mm) by means of fast clip device
ConnectionFrom top and bottom

Tripping Current Range

























Lagging AngleI n>0.01AI n≤0.01A
0.35I n≤I≤1.4I n0.35I n≤I ≤2I n
90°0.25I n≤I≤1.4I n0.25I n≤I ≤2I n
135°0.11I n≤I≤1.4I n0.11I n≤I ≤2In














Detectable wave formPulsating direct current sensitiveSurge current proof
B class
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents,alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents,whether applied suddenly or increasing slowly.

They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.

RCCB’s surge capacity.
Not tripping at standardized 8/20 υs surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

Circuit Diagram




Overall and Installation Dimension(mm)


Application


EV & PV installations
Frequency converters
UPS installations
High-frequency power converters
Building site power supply cabinets
EKL1-63 Type B RCDs can detect sinusoidal AC, pulsating DC, composite of multi-frequency as well as smooth DC residual currents. In addition, tripping conditions are defined with different frequencies from 50Hz to 1kHz. In an AC electrical distribution network, a pure DC residual current can be mainly generated from three-phase rectifying circuits, but also from some specific single phase rectifiers.HENGYI-80B Type B RCD are intended to be used for loads with three-phase rectifier, such as variable speed drives, PV system, EV charging station and medical equipment.



Function
HENGYI-80B Type B Circuit Breaker Control electric circuits.
Protect people against indirect contacts and additionalprotection against direct contacts.
Protect installations against fire hazard due to insulation faults.Residual current circuit breakers are used in housing, tertiarysector and industry Selection Detectable wave form
B class Tripping is ensured for sinusoidal AC residual currents pulsed DCresidual currents,
alternatingresidual sinusoidal currents up to1000Hz, pulsating direct residual EKL1-63B
currents and for smooth directresidual currents, whether applied suddenly or increasing slowly.
Tripping sensitivity 30mA -additional protection against direct contact EKL1-63B.
Tripping time Instantaneous,It ensures instantaneous tripping (without time- delay).


 


Construction and Feature


Elegant appearance; cover and handle in arc shape make comfortable operation.
Contact position indicating window
Transparent cover designed to carry label.
In case of overload to protect circuit, RCCB handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually. Provides protection against earth fault/leakage current and function of isolation.
High short-circuit current withstand capacity EKL1-63B
Applicable to terminal and pin/fork type busbar connection
Equipped with fi nger protected connection terminals EKL1-63B Residual Current Circuit Breaker
Fire resistant plastic parts endures abnormal heating and strong impact
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity. Independent of power supply and line voltage, and free from external interference, voltage fluctuation EKL1-63B single-pole RCCB with two current paths; two-pole RCCB; three-pole RCCB; three-pole RCCB with four current paths, four-pole RCCB Current Circuit Breaker


 