Hot Selling 83060TH 60KVA Frequency Conversion AC Power Supply Power Source 0-300V high power power supply 60KW
The 83 series frequency conversion power supply adopts digital technology and IGBT intelligent output, pure output wave, with excellent technical performance. The power supply has an anti-shock circuit, suitable for various shock loads such as motors and air conditioners; excellent dynamic characteristics, strong load adaptation, high efficiency, simple operation, cost-efficient, suitable for industries such as export electrical appliances plants, laboratories, defense.
Features
1. Output Capacity: 60KVA.
2. Utilize IGBT / PWM technology with switching amplifier design.
3. Adjustable AC output phase voltage0-300V(line voltage 0 – 519.6V)/ frequency 45 - 65Hz;
4. Output voltage stability factor can reach 0.5%;
5. Suitable for single and three phase load. Waveform distortion less than 1% on resistance load;
6. Enhanced crest factor. The rate is up to 3:1 at rating current output.
7. Fast recovering time, 2 milliseconds;
8. Unique regulation function in providing capability to turn on high inrush current loads such as motors and compressors.
9. Over-power, short circuit and over temperature protection and alarm;
10. Recall 7 memories. Able to store voltage, frequency and current high limit setting.
11. Other special requirements can be customized.
Technical Parameters
Input Voltage/Frequency | 380V±10%,50Hz±5% | |||||||||||||
Output Max. Power | Total Power | 9KVA | 15KVA | 30KVA | 45KVA | 60KVA | 75KVA | 90KVA | 100KVA | 120KVA | 150KVA | 180KVA | 200KVA | |
Single Phase Power | 3KVA | 5KVA | 10KVA | 15KVA | 20KVA | 25KVA | 30KVA | 33.3KVA | 40KVA | 50KVA | 60KVA | 66.6KVA | ||
Output Max. Current | 0-150V | 27.27A | 45.45A | 90.90A | 136.3A | 181.8A | 227.2A | 272.7A | 303.0A | 363.6A | 454.5A | 545.4A | 606.0A | |
0-300V | 13.63A | 22.72A | 45.45A | 68.16A | 90.90A | 113.6A | 136.3A | 151.5A | 181.8A | 227.2A | 272.7A | 303.0A | ||
Phase | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | 3Ø/4W | ||
Total Harmonic Distortion (T.H.D) | < 1% :45-65Hz (Resistive Load) | < 1.5% :45-65Hz (Resistive Load) | ||||||||||||
Crest Factor | ≥3 | |||||||||||||
Line Regulation | ± 0.1V | |||||||||||||
Load Regulation | ± (0.5% of output +0.5V) at Resistive Load | |||||||||||||
Response Time | < 2 msec | |||||||||||||
Setting Voltage | Range | 0.0-300.0V | ||||||||||||
Resolution | 0.1V | |||||||||||||
Accuracy | ± (1% of setting + 2counts) | |||||||||||||
Setting Frequency | Range | 45.0-65.0Hz | ||||||||||||
Resolution | 0.1Hz | |||||||||||||
Accuracy | ±(0.02% of setting) | |||||||||||||
Measurement Voltage | Range | 0.0-300.0V(Phase Voltage);0.0-519.6V(Line Voltage) | ||||||||||||
Resolution | 0.1V | |||||||||||||
Accuracy | ± (1% of reading + 2counts) | |||||||||||||
Measurement Frequency | Range | 45.0-65.0Hz | ||||||||||||
Resolution | 0.1Hz | |||||||||||||
Accuracy | ±0.1Hz | |||||||||||||
Measurement Current | Range(A) | L | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 |
M | 9.91-27.27 | 9.91-45.45 | 9.91-90.90 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | 9.91-99.00 | ||
H | - | - | - | 99.1-136.3 | 99.1-181.8 | 99.1-227.2 | 99.1-272.7 | 99.1-303.0 | 99.1-363.6 | 99.1-454.5 | 99.1-545.4 | 99.1-606.0 | ||
Resolution | 0.001A/0.01A/0.1A | |||||||||||||
Accuracy | L:±(1% of reading +5counts);M&H:± (1% of reading +1count) | |||||||||||||
Measurement Power | Range(KW) | L | 0.000-9.000 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 | 0.000-9.900 |
M | - | 9.90-15.00 | 9.90-30.00 | 9.90-55.00 | 9.90-60.00 | 9.90-75.00 | 9.90-90.00 | 9.90-99.00 | 9.90-99.00 | 9.90-99.00 | 9.90-99.00 | 9.90-99.00 | ||
H | - | - | - | - | - | - | - | 99.1-100.0 | 99.1-120.0 | 99.1-150.0 | 99.1-180.0 | 99.1-200.0 | ||
Resolution | 0.001KW/0.01KW/0.1KW | |||||||||||||
Accuracy | ±(1.5% of reading +5counts) | |||||||||||||
Power Factor | Range | 0.000-1.000 | ||||||||||||
Resolution | 0.001 | |||||||||||||
Dimension W X D X H(mm) | 550X800X950 | 550X800X950 | 600X1000X1105 | 650X1200X1155 | 650X1200X1155 | 650×1350×1205 | 800X1500X1255 | 800X1500X1255 | 850X1800X1455 | 850WX2200DX1755H | 850WX2200DX1755H | 850WX2200DX1755H | ||
General Specifications | ||||||||||||||
Memory | 7 memories | |||||||||||||
Auto Voltage Adjust | Enable it for improve voltage regulation within ±0.1V | |||||||||||||
Efficiency | 80%(at Full Load) | |||||||||||||
Protection | Over Load , Short Circuit , Over Temperature | |||||||||||||
Calibration | Front Panel Calibration | |||||||||||||
Environment | 0-40℃/20-80%RH | |||||||||||||
Constant Current Output | Standard | |||||||||||||
Communicating Function | RS232(Standard)/RS485(Optional) | |||||||||||||
PLC Remote(Optional) | O/P:ON/OFF |
3.Product introduction
Usage | Safety tester |
MOQ | No MOQ |
Capacity | 100 sets/Month |
Package | plywood box or as customer requirements |
Lead time | 15-30 days based on the order quantity |
Payment Terms | 30% deposit in advance, 70% before shipment |
Payment methods | T/T or Western Union |
QC | 100% inspect before packing, Spot inspect before shipping |
4. Contact