Best Price High Utility Anesthesia Machine Ysenmed YSAV602 for Hospital


 2017-7-7_01


YSAV602.jpg


2017-7-7_02


YSAV602 Anesthesia Machine, designed with state-of-the-art technologies, is one of high utility with excellent performance and complete functions. Both outstanding and inexpensive, it has the best cost performance that can satisfy any customer.
The Ventilator adopts microcomputer control with high-definition 5.7” LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
Reliable pneumatic transmission system.
Economic and proper configuration of technologies, optional as required by the Customer.
Modularized design and upgrading. Upgrading is available as required by the Customer.


 


Specifications

































































































Part of Anesthesia
Main bodyHigh-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of application adult, child
Gas sourceO2, N2O: 0.27~0.55MPa
Flow meterO2, N2O : 0.1~1.0L/min 
O2, N2O linkage and N2O StopperWhen using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off
Flow rate of rapid oxygen supply25~75L/min 
Low oxygen pressure alarmThere will be sound alarm when the oxygen
pressure < 0.2MPa
Vaporizer it has the function of automatic compensation based on pressure,temperature,and flow rate. The regulation range of evaporator concentration is 0~5 vol%. 

Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer.


Respiratory circuitworking mode: all-close, semi-close, semi-open
releasing pressure: 0.5~7kPa
Respiratory bellowsbellows for adults, bellows for children
tidal volume range:0~1500 ml
Part of Ventilator
Display modeHigh-definition 5.7” LCD screen display
Ventilation modeIPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate)
Ventilation parametersTidal volume 50~1500ml; Rate 2~99 bpm; I:E 2:1~1:8; Pressure range 1.0~6.0 kPa; Inspiratory trigger pressure -1.0~2.0 kPa; PEEP 0~2.0 kPa; SIGH 1.5 times the inspiratory time
Parameters for ventilation monitoringtidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
Security Alarm System
Oxygen Concentration alarmupper limit setting range (50%~100%)
low limit setting range (15%~50%)
Airway pressure alarmupper limit setting range 1.0~6.0 kPa
low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarmupper limit setting range 3.0~30L
low limit setting range 1.0~10L
Sustained high-pressure alarmit will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarmit will give sound and light alarm if there is
no tidal volume input in 15s
Power alarm
PowerAC 220V±10%     50Hz±1Hz

 


2017-7-7_032017-7-7_042017-7-7_052017-7-7_06_01


 