Test Function | Range | Accuracy | Resolution |
2、3、4 wire method for measuring ground resistance (Re) | 0.00Ω~29.99Ω | ±2%rdg±5dgt(remark 1) | 0.01Ω |
30.0Ω~299.9Ω | ±2%rdg±3dgt | 0.1Ω | |
300Ω~2999Ω | ±2%rdg±3dgt | 1Ω | |
3.00kΩ~30.00kΩ | ±2%rdg±3dgt | 10Ω | |
DC resistance(Re) | 0.0Ω~299.9Ω | ±2%rdg±3dgt | 0.1Ω |
300Ω~2999Ω | ±2%rdg±3dgt | 1Ω | |
3.00kΩ~30.00kΩ | ±2%rdg±3dgt | 10Ω | |
Selection method for measuring ground resistance(Re) | 0.00Ω~29.99Ω | ±2%rdg±5dgt(remark 1) | 0.01Ω |
30.0Ω~299.9Ω | ±2%rdg±3dgt | 0.1Ω | |
300Ω~3000Ω | ±2%rdg±3dgt | 1Ω | |
Double clamp method for measuring ground resistance (Re) | 0.01Ω~0.99Ω | ±10%rdg±10dgt | 0.01Ω |
1.0Ω~9.9Ω | 0.1Ω | ||
10Ω~100Ω | 1Ω | ||
Soil resistivity(ρ) | 0.00Ωm~99.99Ωm | ρ=2πaR (remark 2) | 0.01Ωm |
100.0Ωm~999.9Ωm | 0.1Ωm | ||
1000Ωm~9999Ωm | 1Ωm | ||
10.00kΩm~99.99kΩm | 10Ωm | ||
100.0kΩm~999.9kΩm | 100Ωm | ||
1000kΩm~9999kΩm | 1kΩm | ||
Ground voltage | AC 0.00~100.0V | ±2%rdg±3dgt | 0.01V |
AC current | AC 0.0mA~1000A | ±2%rdg±3dgt | 0.1mA |
Function | Ground resistance、Soil resistivity、DC resistance、Ground voltage、AC current |
Ambient temperature and humidity | 23℃±5℃,below 75%rh |
Interference voltage | <20V (should be avoided) |
Interference current | <2A (should be avoided) |
Measure R electrode spacing | a>5d |
Measured ρelectrode spacing | a>20h |
Power | DC 6V 4.5Ah lead-acid battery lasts more than 100 hours standby |
Backlight | Controllable backlight, suitable for use in dim places |
measurement mode | Precise four-wire、 three-wire measurement, simple two-wire measurement、Selection method, double clamp method for measuring grounding resistance |
Measurement methods | 2.3.4-wire method measurement: Polarization method, measuring current 20mA Max Soil resistivity: four-pole method Selectivity Measurement: Polarization Method, Measuring Current 20mA Max Double clamp method: non-contact mutual inductance measurement method, test current 1mA Max DC resistance: polarization method AC current: average rectification (clamp) Ground Voltage: Average Rectification(between S-ES interface) |
Test voltage waveform | Sine wave |
Test frequency | 128Hz |
Short circuit test current | AC 20mA max |
Open circuit test voltage | AC 28V max |
Electrode spacing range | 1m~100m |
Display mode | 4-bit large LCD display, with backlight |
Measurement instructions | LED flashing indicator during measurement |
LCD size | 111mm×68mm |
LCD display field | 108mm×65mm |
Instrument size | L/W/H:277.2mm×227.5mm×153mm |
Clamp size | L/T/H:101mm×27mm×214mm |
Test line | 4 strips:red 15m,black 15m, yellow 10m,green 10m each one |
Simple test line | 2strips:yellow 1.5m,green 1.5m each one |
Auxiliary Grounding rod | 4PCS:φ10mm×200mm |
Current clamp | 2PCS:φ4 mm Banana plug |
Current clamp diameter | φ50mm |
Current clamp lead | Length 2m |
Measure time | AC current:about 2 times/sec; Ground voltage:about 2 times/sec; grounding resistance、soil resistivity: about 7 seconds/time |
Line voltage | Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power) |
USB interface | With USB interface, storage data can be uploaded to the computer, save and print |
Communication Line | One USB communication line, 1.5m long |
Data storage | 500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full |
Data review | Data review function: "MR" symbol display |
Overflow display | Over-range overflow function: "OL" symbol display |
Current clamp low current indication | When measuring by the selection method or the double-clamp method, when the current signal received by the current clamp A is lower than 0.5 mA, the symbol “ ” is displayed, and at this time, the clamping direction of the current clamp A should be checked. |
Interference test | Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V |
Auxiliary grounding test | With auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ) |
Alarm function | Alarm when the measured value exceeds the alarm setting value |
Battery voltage | Real-time display of battery power, reminding timely charging when battery voltage is low |
Automatic Shutdown | “APO” Indicates, automatic Shutdown After 15 Minutes |
Power consumption | Standby: 40mA Max(Backlight off) |
Turn on backlight: 43mA Max | |
measuring:120mA Max(Backlight off) | |
Weight | Instrument: 2450g(including battery) |
Current clamp:940g(2PCS) | |
Test lines:1300g(including simple test line) | |
Auxiliary grounding rod: 850g(4PCS) | |
Working temperature and humidity | -10℃~40℃;below 80%rh |
Storage temperature and humidity | -20℃~60℃;below 70%rh |
Overload protection | Grounding resistance:AC 280V/3 seconds between H-E and S-ES ports |
Insulation resistance | 20MΩ以上(500V between circuit and housing) |
Pressure resistance | AC 3700V/rms(between circuit and housing) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、pollution level 2); IEC61010-031; IEC61557-1(grounding resistance); IEC61557-5(soil resistivity); JJG 366-2004. JJG 366-2004(ground resistance meter); JJG 1054-2009(Clamp grounding resistance meter). |
Instrument | 1PC |
Instrument bag | 1PC |
Auxiliary grounding rod | 4PCS |
Current clamp | 2PCS |
Monitoring software CD | 1PC |
USB communication line | 1PC |
Test line | 4PCS |
Simple test line | 2PCS |
6V Battery (built-in) | 1PC |
charger | 1PC |
Manual, certificate | 1SET |