Многофункциональный тестер сопротивления заземления ES3002 С Двойным Зажимом портативный


Поделиться:


Цена:470,00 $ - 580,00 $*

Количество:



Описание и отзывы


Трекер стоимости

Месяц Минимальная цена Макс. стоимость
Sep-17-2025 559.31 $* 587.31 $*
Aug-17-2025 555.90 $* 583.42 $*
Jul-17-2025 465.11 $* 488.89 $*
Jun-17-2025 545.34 $* 572.68 $*
May-17-2025 475.66 $* 499.79 $*
Apr-17-2025 536.9 $* 563.28 $*
Mar-17-2025 531.41 $* 558.33 $*
Feb-17-2025 526.76 $* 552.92 $*
Jan-17-2025 522.27 $* 548.31 $*

Характеристики



Recommend Products




Products Display




Product Description


ES3002 Double clamp multi-function grounding resistance tester is also called double clamp grounding resistance tester, The advanced grounding resistance tester integrates a variety of measurement methods. In addition to the traditional function of ancillary grounding resistance, it also has the unique function of measuring without auxiliary ground. It uses a large LCD gray screen backlight display and microprocessor technology, through the microprocessor-controlled 2-wire, 3-wire, 4-wire, selection method, double clamp method to test ground resistance. Large-diameter current clamp design, using double jaw measurement technology, without the need to hit the auxiliary ground, without the need to isolate the grounding body and equipment to achieve on-line measurement. Widely used in telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding networks, lightning rods and so on.The instrument has the characteristics of precise, fast, simple, stable and reliable.
ES3002 Double clamp multi-function grounding resistance tester is controlled by a microprocessor and can accurately detect ground resistance, soil resistivity, ground voltage, DC voltage and AC current. It uses a fast filtering technique to minimize interference. Displaying the resistance value of the auxiliary electrode in the same screen, which is convenient for judging the measurement error caused by environmental factors, facilitating more accurate measurement of the grounding true resistance value, and storing 500 sets of data at the same time.The online monitoring data can be monitored by the monitoring software. USB data can be uploaded to the PC and has unique functions such as numerical maintenance and intelligent alarm prompting.
ES3002 Double clamp multi-function grounding resistance tester consists of host computer, monitoring software, test line, USB cable, and grounding pin. It has the functions of reading, checking, saving, reporting and printing of historical data.


Main Feature


Function:\tGrounding resistance、soil resistivity、DC resistance、grounding voltage、AC current
Resistance range:\t0.01Ω~30.00kΩ
Soil resistivity(ρ):\t0.00Ωm~9999kΩm
Grounding voltage:\tAC 0.00~100.0V
AC current:\tAC 0.0mA~1000A
Test mode:\tPrecision four-wire, three-wire method measurement, simple two-wire, selection method, double clamp method to measure grounding resistance


Technical Data


1.Range and Accuracy error


Test Function
Range
Accuracy
Resolution
2、3、4 wire method for measuring ground resistance (Re)
0.00Ω~29.99Ω
±2%rdg±5dgt(remark 1)
0.01Ω
30.0Ω~299.9Ω
±2%rdg±3dgt
0.1Ω
300Ω~2999Ω
±2%rdg±3dgt
3.00kΩ~30.00kΩ
±2%rdg±3dgt
10Ω
DC resistance(Re)
0.0Ω~299.9Ω
±2%rdg±3dgt
0.1Ω
300Ω~2999Ω
±2%rdg±3dgt
3.00kΩ~30.00kΩ
±2%rdg±3dgt
10Ω
Selection method for measuring ground resistance(Re)
0.00Ω~29.99Ω
±2%rdg±5dgt(remark 1)
0.01Ω
30.0Ω~299.9Ω
±2%rdg±3dgt
0.1Ω
300Ω~3000Ω
±2%rdg±3dgt
Double clamp method for measuring ground resistance (Re)
0.01Ω~0.99Ω
±10%rdg±10dgt
0.01Ω
1.0Ω~9.9Ω
0.1Ω
10Ω~100Ω
Soil resistivity(ρ)
0.00Ωm~99.99Ωm
ρ=2πaR (remark 2)
0.01Ωm
100.0Ωm~999.9Ωm
0.1Ωm
1000Ωm~9999Ωm
1Ωm
10.00kΩm~99.99kΩm
10Ωm
100.0kΩm~999.9kΩm
100Ωm
1000kΩm~9999kΩm
1kΩm
Ground voltage
AC 0.00~100.0V
±2%rdg±3dgt
0.01V
AC current
AC 0.0mA~1000A
±2%rdg±3dgt
0.1mA


Remark:
1. Reference conditions: accuracy with Rh Rs < 100Ω。
Working conditions:Rh max=3kΩ+100R<50kΩ;Rs max=3kΩ+100R<50kΩ
2.Depends on the measurement accuracy of R,π=3.14, a:1 m~100m;


2.General specification


Function
Ground resistance、Soil resistivity、DC resistance、Ground voltage、AC current
Ambient temperature and humidity
23℃±5℃,below 75%rh
Interference voltage
<20V (should be avoided)
Interference current
<2A (should be avoided)
Measure R electrode spacing
a>5d
Measured ρelectrode spacing
a>20h
Power
DC 6V 4.5Ah lead-acid battery lasts more than 100 hours standby
Backlight
Controllable backlight, suitable for use in dim places
measurement mode
Precise four-wire、 three-wire measurement, simple two-wire measurement、Selection method, double clamp method for measuring
grounding resistance
Measurement methods
2.3.4-wire method measurement: Polarization method, measuring current 20mA Max
Soil resistivity: four-pole method
Selectivity Measurement: Polarization Method, Measuring Current 20mA Max
Double clamp method: non-contact mutual inductance measurement method, test current 1mA Max
DC resistance: polarization method
AC current: average rectification (clamp)
Ground Voltage: Average Rectification(between S-ES interface)
Test voltage waveform
Sine wave
Test frequency
128Hz
Short circuit test current
AC 20mA max
Open circuit test voltage
AC 28V max
Electrode spacing range
1m~100m
Display mode
4-bit large LCD display, with backlight
Measurement instructions
LED flashing indicator during measurement
LCD size
111mm×68mm
LCD display field
108mm×65mm
Instrument size
L/W/H:277.2mm×227.5mm×153mm
Clamp size
L/T/H:101mm×27mm×214mm
Test line
4 strips:red 15m,black 15m, yellow 10m,green 10m each one
Simple test line
2strips:yellow 1.5m,green 1.5m each one
Auxiliary Grounding rod
4PCS:φ10mm×200mm
Current clamp
2PCS:φ4 mm Banana plug
Current clamp diameter
φ50mm
Current clamp lead
Length 2m
Measure time
AC current:about 2 times/sec;
Ground voltage:about 2 times/sec;
grounding resistance、soil resistivity: about 7 seconds/time
Line voltage
Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power)
USB interface
With USB interface, storage data can be uploaded to the computer, save and print
Communication Line
One USB communication line, 1.5m long
Data storage
500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full
Data review
Data review function: "MR" symbol display
Overflow display
Over-range overflow function: "OL" symbol display
Current clamp low current indication
When measuring by the selection method or the double-clamp method, when the current signal received by the current clamp A is
lower than 0.5 mA, the symbol “ ” is displayed, and at this time, the clamping direction of the current clamp A should be checked.
Interference test
Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V
Auxiliary grounding test
With auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ)
Alarm function
Alarm when the measured value exceeds the alarm setting value
Battery voltage
Real-time display of battery power, reminding timely charging when battery voltage is low
Automatic Shutdown
“APO” Indicates, automatic Shutdown After 15 Minutes
Power consumption
Standby: 40mA Max(Backlight off)
Turn on backlight: 43mA Max
measuring:120mA Max(Backlight off)
Weight
Instrument: 2450g(including battery)
Current clamp:940g(2PCS)
Test lines:1300g(including simple test line)
Auxiliary grounding rod: 850g(4PCS)
Working temperature and humidity
-10℃~40℃;below 80%rh
Storage temperature and humidity
-20℃~60℃;below 70%rh
Overload protection
Grounding resistance:AC 280V/3 seconds between H-E and S-ES ports
Insulation resistance
20MΩ以上(500V between circuit and housing)
Pressure resistance
AC 3700V/rms(between circuit and housing)
Electromagnetic properties
IEC61326(EMC)
Suitable for safety regulations
IEC61010-1(CAT Ⅲ 300V、CAT IV 150V、pollution level 2);
IEC61010-031;
IEC61557-1(grounding resistance);
IEC61557-5(soil resistivity);
JJG 366-2004.
JJG 366-2004(ground resistance meter);
JJG 1054-2009(Clamp grounding resistance meter).


Standard Delivery


Instrument
1PC
Instrument bag
1PC
Auxiliary grounding rod
4PCS
Current clamp
2PCS
Monitoring software CD
1PC
USB communication line
1PC
Test line
4PCS
Simple test line
2PCS
6V Battery (built-in)
1PC
charger
1PC
Manual, certificate
1SET


FAQ


If you want to know more details, welcome to contact us.
Lin Gao
Zibo Senyuan Electric Co., Ltd.
Email:senyuan@zbsywm.com
Mobile/WhatsApp: ( 0086) 13869301972


Q: Is there an OEM service?
A: As the trusted and professional supplier, we accept the sample order, even for one piece. Also provide the OEM service, sample order is OK.


Q: Which payment methods are supported?
A: As the trusted and professional supplier, we accept the sample order, even for one piece. Also provide the OEM service, sample order is OK.


Q: Do you support after sales service?
A: Most products we provide warranty of 12months, some with the longer warranty of 24months.


Похожие товары

Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com