Характеристики



Products Description








Model
cooling water consumption
Cooling capacityKcal/h
Fan deliverym3/h
Working water flow m3/h
Inlet and outlet pipe diametermm
Circulating tank volume L
Weight
KG
KCBL-01
10T
30000
9700
4-8
67
400
350
KCBL-02
20T
45000
14900
8-16
67
400
650
KCBL-04
30T
110000
26400
12-23
67
400
1000
KCBL-06
40T
180000
38000
23-32
76
500
1400
KCBL-08
50T
260000
51600
27-37
76
500
2150
KCBL-10
60T
350000
51600
28-39
76
1000
2400
KCBL-11
70T
400000
51600
28-41
89
1000
2400
KCBL-12
80T
450000
103200
8-41
89
1000
2500


Product feature
During the working process of the cooling system, the cooling medium (soft water, quench liquid) is driven by the main circulating pump Circulating flow between heat exchanger (copper condenser) and cooling equipment (such as power supply, cooling workpiece, etc.); Spray water evenly over the heat exchanger On the surface of the heat exchanger to form a uniform water film, the cold air from the tower body below the air inlet into the system theme, and the spray water countercurrent through On the surface of heat exchanger, there are two heat transfer modes in this process, namely heat conduction between cold air and cooling medium and heat exchange between spray water evaporation and heat absorption In exchange, the saturated hot and wet air after absorbing the heat is discharged to the atmosphere by the fan, and the rest of the spray water flows into the tank at the bottom of the tower body and is transported by the water pump To spray system. In this way, the cooling medium in the heat exchanger is cooled and cooled.


technical feature
1.Working fluid (soft water or other liquid) circulates in the coil of closed cooling tower. After the heat of fluid is absorbed by the pipe wall of coil, the heat of pipe wall is discharged out of the machine through the fan on the top.
2.When the fluid temperature is too high (beyond the set temperature), the spray system will be automatically started. The spray pump will spray water on the hot and humid pipe wall and form a water film, which will absorb a lot of heat (latent heat of evaporation) through evaporation.Some of the spray water turns into steam, which is carried away by the moving air, and the unevaporated water drops into the collecting tank for the next cycle.The fluid in the coil circulates in a closed loop and theoretically there is no consumption.Spray water consumption is only 0.1-0.2% of the unit flow.
3.Fully enclosed circulation cooling ensures the purity of the medium and eliminates the blockage of pipes caused by sundries.

.4.Soft water circulation cooling, no scale generation caused by the induction heating power, induction coil and other overheating damage.
5Automatic digital display temperature control, energy saving.



Product application
Cooling in induction heating high, medium frequency quenching equipment, medium frequency power supply and electric furnace, induction dithermic furnace, protection Cooling of warm furnace, etc.;  The cooling of circulating water of various reactors and condensers in chemical industry;  Metal die casting mold, injection mold and other large mold cold. But;  Cooling of industrial solution, such as quenching solution, electroplating solution, etc.


Why choose us




Our company






Company profile
Zhengzhou kechuang Electronics Co.,Ltd was established in 31th,August 2001.Kechuang has been developed hundreds of products which has been widely spread and enjoyed by both national and international market since 2001. In 2016,in order to meet the high-end users' demand both in domestic and overseas.We produced much higher performance,higher percision and higher cost-effective intelligent IGBT power supply. Kechuang always has always regard "more energy-saving","more reliable" as the product development direction.Completing the products automatic,intelligent and robotic functions , which leads in the first of national induction heating technology.All of our products and technologies can provide.


Exhibition






Certifications




Packing & Delivery


delicately packed
Hot forging machine welding equipment annealing furnace induction heater packed in wooden.We can also
ustomize the packaging according to your requirements


Our Service


Pre-Sales Service
* Inquiry and consulting support.
* Sample testing support.
* View our Factory.
After-Sales Service
* Training how to instal the machine, training how to use the machine.
* Engineers available to service machinery overseas.






Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com