Ophthalmic pachymeter
OD1-A A Scan
OD1-P pachymeter scan
OD1-AP A Scan and pachymeter
FUNCTION
@5.7 -inch color LCD touch screen, and user information can be easily input, more convenient and quick
@. Light blue and white alternate design, select the user interface of the color matching, reduce the visual fatigue, protect your eyes.
@I - Station integrated workstation, complete data and waveform storage, report generation and printing function
@Rechargeable battery, could be used for 10 hours.
@Built-in thermal printer, A key print directly.
@USB port could connect your PC directly
@Support I-station workstation connection
@Small footswitch offer you good feeling.
@Six kinds language: Chinese, English, Russian, French, Spanish and Portuguese.
@1.7Kg net weight, more portable.
@show actual value and deviation at the same time
@Sensitive , convenient, accurate and fast measurement
@The probe service life is long, high cost performance
@Point and surface point measurement display
calculate the calibration value of intraocular pressure (after achieving accurate intraocular pressure)
@Ultrasonic velocity and offset is adjustable, compare measuring results with other equipment easily.
@Unique design with nearly 20 years of manufacturing technology, increase the stability and accuracy of measurement
Technology Parameter:
.
A SCANNER
A scan probe: 10MHz import small size probe, built-in luminotron
Measuring range: 15mm-40mm
Measurement precision: ±0. 05mm; with macula lutea trace function
Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
Method of measurement: immersion and contact
Eye mode: Phakic/ Aphakic/Dense/ various IOL
IOL formula:SRK-II,SRK-T,BINKHORST- Ⅱ,HOLLADAY,HOFFER-Q,
HAIGIS
Enter the name & ID; easy to check archive
Storage: 10 cases, 5 readings each case
Output: A scan waveform and IOL calculation sheet
Pachymeter:
Probe frequency: 20 Mhz
Resolution: 1um
Measurement range: 0.23~1.3mm
Accuracy: ±5um
Pachymeter measurement ways :
Single-point measurement
Five points measurement
Nine points measurement
Power requirement: AC 100-240V 50-60Hz
Rate power: <= 45 VA
Dimension: 200*168*165(mm, L*W*H)
Weight of main unit: approx. 1.7kg (exclude the accessories)
Accessories:
Adapter
Gage block
Battery charger Optional
Battery optional
Touch screen pen
Footswitch
A Probe frequency | 10MHz import small size probe, built-in luminotron |
Measuring range | 15mm-40mm |
Measurement precision | ±0. 05mm; with macula lutea trace function |
Measurement | Anterior chamber depth, lens thickness, vitreous body length, total length and average |
IOL formula | SRK-II,SRK-T,BINKHORST- Ⅱ,HOLLADAY,HOFFER-Q, HAIGIS |
Storage | 10 cases, 5 readings each case |