High-voltage generator | ||
Power | 100kW | |
Maximum current | 1000mA | |
Maximum tube voltage | 125KV | |
X-ray tube unit | ||
Dual focus | Small 0.6mm, large 1.0mm | |
Cooling method | Advanced WAD cooling technology | |
Advanced technology | Liquid metal bearing technology | |
Dynamic flat panel detector | ||
Material | A-Si Cesium Iodide | |
Nominal area | 30cm×30cm | |
A/D range | 16 bit | |
DQE | 77% | |
Automatic collimator | ||
The automatic insertion technology is adopted to eliminate the soft rays of the tube without manual intervention. | ||
Electric lung field iris | ||
Automatic X-ray filed adjustment | ||
Gantry system | ||
The lastest 7-axis gantry design covers small area, projects different surgical spot of patient easily and fully meet the installation requirements of compound intervention operating room | ||
R-axis rotation range | 300° | |
P-axis rotation range | 316° | |
O-axis rotation range | 256° | |
A-axis | CRA/CAU 105° | |
RAO | 120° | |
LAO | 180° | |
Anti-collision device on tube | ||
Automatic laser positioning function | ||
Catheterization table | ||
Full caron fiber floating table surface | ||
Length× Width | 300cm × 63.5cm | |
Vertical movement range | 140cm | |
Lateral movement range | 36cm | |
The lowest height | 72cm | |
Image acquisition & Processing system | ||
Acquisition mode: CINE, DSA, rotating DSA/ rotating acquisition, DA acquisition, Fluoroscopy, lower limb stepping DSA acquisition | ||
Post-processing function: Automatic image window width/position adjustment, additional annotations, image selection, zoom, image roaming, road sign image selection, electronic shutter, edge enhancement, image inversion, image rotation and mirroring functions, etc. | ||
Image post-processing system(option) | ||
3D acquisition & reconstruction | ||
Cerebrovascular 3D DSA | ||
CT-like reconstruction | ||
3D image rendering | ||
Vascular tissues fluoroscopy function | ||
Interface | ||
High Pressure Syringe interface | ||
Standard video output interface supports video broadcast and can be used for conferences, teaching, image browsing in waiting area for family members, etc. | ||
Image storage and playback | ||
Host hard disk images can be stored on CD/DVD, the storage capacity can reach: 1024×1024 matrix, 16bit, 1,000,000 images | ||
Acquisition sequence automatic playback | ||
DICOM | ||
DICOM connectivity detection function; DICOM function to get patient information list; DICOM dose report function; DICOM print function; DOCOM CD/DVD burn function; DICOM USB export function | ||
Others | ||
System can be upgraded | ||
Intercom system | ||
English operation interface | ||
English user manual |