Характеристики



Products Description


Energy efficiency standards
Comply with GB30253-1 grade
Work mode
S1
Installation dimensions
Comply with IEC standard
Control mode
Variable frequency vector control
Power range
7.5 〜160kW
Governing range
constant torque: 0〜3000r/min
Cooling way
IC411 (fan cooling)
weak magnet: 3000 〜3600r/min
Power range
7.5 〜250kW
Governing range
Constant torque: 0〜1500r/min
Cooling way
IC416 (independent axial flow fan)
Weak magnet: 1500 〜1800r/min
Insulation class
F
Optional parts
Encoder, spiral transformer, PTC, PT100
Protection grade
IP54 (IP23 customizabe)
Wiring type
Junction box (aviation plug can be customized as per requirement)
installation
IMB3 IMB5 IMB35
Service factor
Standard 1, 2 (customized as per requirement)
Required environment
below 1000m altitude
Temperature -15〜45°C
Relative humidity below 90%


Model
Power
(kW)
Rated volt (V)
Rated current
(A)
Frequency 
(Hz)
No. of poles
Rated torque
(N • m )
Efficiency
(%)
Weight
(kg)
TYB-132M1-6
7.5
380
14.5
75
6
47.8
92.6
61
TYB-132M2-6
11
380
21
75
6
70
93.6
73
TYB-160M1-6
11
380
210
75
6
70
93.6
108
TYB-160M2-6
15
380
28.5
75
6
95.B
94
124
TYB-160L1-6
18.5
380
35.1
75
6
117.8
94.3
132
TYB-160L2-6
22
380
415
75
6
140
94.7
141
TYB-225S1-8
30
B80
56.4
100
8
191
95
261
TYB-225S2-8
37
380
69.4
100
8
235.6
953
274
TYB-225M1-8
45
380
84.1
100
8
286.5
95.6
284
TYB-225M2-8
55
380
102.6
100
8
350
95.8
297
TYB-225MX-8
75
380
141.7
100
8
477.5
96
336
TYB-280S-8
90
380
169.7
100
8
573
96.2
484
TYB-280M1-8
110
380
207
100
8
700
96.4
512
TYB-280M2-8
132
380
248.1
100
8
840
96.5
555
TYB-315S-8
160
380
300.8
100
8
1018.7
96.5
756
TYB-315M-8
200
380
375.6
100
8
1273.3
96.6
850
TYB-315L1-8
220
380
413.2
100
8
14007
96.6
910
TYB-315L2-8
250
380
469.1
100
8
15917
96.7
1055


Model
Power (kW)
Rated volt ( V)
Rated current (A)
Frequency (Hz)
No. of poles
Rated torque
(N • m )
Efficiency
(%)
Weight
(kg)
TYB-132M1-4
7.5
380
14.6
100
4
23.9
92.1
71
TYB-132M2-4
11
380
21.1
100
4
35
93
87
TYB-160M1-4
15
380
28.7
100
4
47.8
93.4
118
TYB-160M2-4
22
380
41.7
100
4
70
94.4
126
TYB-180M1-4
30
380
56.7
100
4
95.5
94.5
175
TYB-180M2-4
37
380
69.8
100
4
117.8
94.8
186
TYB-200L1-4
45
380
84.6
100
4
142.3
95.1
241
TYB-200L2-4
55
380
103.1
100
4
175
95.4
259
TYB-225M-4
75
380
141
100
4
238.8
95.6
388
TYB-225MX-4
90
380
168.7
100
4
286.5
95.8
421
TYB-280S1-8
110
380
205.7
200
8
350
96
486
TYB-280S2-8
132
380
246.9
200
8
420
96
534
TYB-280M-8
160
380
398.6
200
8
509
96.2
698


Details Images






Loss Analysis




Permanent magnet synchronous motor 

can reduce iron loss and primary copper 

loss with no secondary copper loss.


High efficiency NdFeB permanent magnet is adopted, with no excitation loss. Special rotor structure design has greatly reduced the iron loss and stray loss. The motor efficiency is above IE4 standard, Compared with three-phase asynchronous motor, the efficiency is improved by 5-10% and power factor is increased by 10-15%.

High efficiency and high power factor can be maintained in the load range of 20% to 120%. The power factor can be 1, while three-phase asynchronous motor can only reach 0.86,it effectively reduces the cabling loss, and improves the utilization rate of the power grid. Energy saving is more significant under light load.

Standard type motor efficiency is equivalent to IE3 (high efficiency:>GB2 grade)
General type motor efficiency is above IE4 (ultra high efficiency:>GB1 grade)


Comparison of Motor Efficiency


1) The efficiency of the above asynchronous motor is JISC 4210.

2) The efficiency of the above standard type synchronous motor is the value of IE3 specified in IEC 60034-30.

3) The above general type synchronous motor efficiency is the value of IE4 specified in IEC 60034-30.

More energy saved by combined operation
By combining the synchronous motor with an independent frequency converter for energy-saving control, the power loss can be reduced and further high efficiency operation can be realized.





Main Features


1.Small and Light
Volume ratio: average 35% smaller, weight ratio: average 40% lighter
Motor frame No. is decreased by 1 ~ 3, compared with asynchronous motor.
It can realize mechanical miniaturization to save space.


2.High Power Factor
Reduce the capacity of power receiving equipment.
There is no doubt of high efficiency. Compared with asynchronous motor, it may reduce the current volume of equipment due to high power factor.

3. High Efficiency•Energy Saving
Motor efficiency is equal to IE4 (High efficiency: above GB1 level)


Factory Show






FAQ


1.What is the heat resistance rating of permanent magnets? What will cause demagnetization?
The permanent magnets commonly used in our company are neodymium-boron-iron materials, and their maximum operating temperature is different depending on the grades used. For example, N38EH, the maximum working temperature of its material can reach 200℃, but we redesign it according to 180℃ as the limit.
To put it simply, our products are designed with sufficient margin, and there will be no demagnetization due to high temperature during use. As long as there is no high current impact, the permanent magnets of the motor will not demagnetize, and the use of inverters can avoid the occurrence of high currents.

2. What is the usual noise of the motor running?
Motor noise varies greatly depending on the specifications of the motor. Permanent magnet motors running below 200 rpm usually have a noise below 80dab. The noise of permanent magnet motors with operating speeds above 750 rpm is generally around 85dab.
Meet the relevant regulations of GB100693.-2008 "Rotating Electric Machine Noise Measurement Method and Limits".

3. What are the contents of operation and maintenance?
The motor basically has no operating costs and only requires routine maintenance. If the environment is poor, the motor with the external fan and the attachments of the external fan need to be cleaned regularly to avoid additional power loss.


Contact Us


Qingdao Enneng Motor Co.,ltd
Tel:
+86 532 66000559
Email:
sales@enpmsm.com
Mobile:
+86 18562780228
Website:
www.enpmsm.com
Address:
D2-3 Building, Ti Park, No.2 Xiuyuan Road,High-Tech Zone,
Qingdao, Shandong, China


Похожие товары

Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com