Quality Appearance
Integral molding rice gold, compact structure, elegant and beautiful appearance, electrostatic spraying, durable. The special wind hood is made of the latest "modified polypropylene" material, which has strong anti-ultraviolet properties and is not easy to be aging and deformed.
Ultra-Low Temperature
The cooling and heating are fast, the efficiency is high, and the performance is better than international. The nominal heating COP can reach 2.6, and the comprehensive partial load performance of heating results in an IPLV of 2.95. The unit can operate stably under a wide temperature environment of -30°C-43°C.
Efficient Heat Transfer
The evaporating side heat exchanger adopts special internally threaded copper tubes and high-efficiency heat exchange fins, and the wind turbine airflow angle is
optimized to match the best operating speed, with higher efficiency and lower noise.
Wide Voltage Operation
The unit can operate under a wide voltage, avoiding unstable operation of the unit due to power grid waves in some areas, and realizing "on-demand output according to the indoor environment and temperature, reducing unnecessary power loss."
Full DC Inverter Compressor
The heat pump is used to test the full DC frequency conversion compressor, which can precisely control the operating speed of the compressor and fan, quickly heat up, and achieve high power and high efficiency of the unit, which has obvious advantages in energy saving.
Enjoy Both Cold and Warm
It combines heating in winter and cooling in summer, with one machine for dual purposes. The self-developed intelligent defrosting control program is adopted, with frost and defrost, normal heating without frost, and intelligent judgment to ensure the optimal heating capacity and higher energy efficiency ratio.
R410A Refrigerant
R410A Refrigerant is a new type of anti-corrosion protection system; it is profitable, does not destroy the ozone development, and has high heating efficiency. It has special characteristics such as superior toxic properties, and
even worse protection.
Power-Off Memory
According to the customer's habits or power supply characteristics, the user can freely choose whether to enable the power-down memory function. After the power-off memory function is selected, when the power supply is restored, the unit will return to the state before the power failure.
Specification
| Model | KFXRS-030H-BDW | KFXRS-050H-BDW | KFXRS-060H-BDW | | | |
| Heating Capacity/COP | 5800W/2. 41 | 9500W/2. 41 | 11000W/2.41 | | | |
| Heating Input Power/Current | 2400W/11. 2A | 3940W/18.5A | 4560W/21.3A | | | |
| Cooling Capacity/EER | 7000W/2 .7 | 12000W/2.7 | 13500W/2.7 | | | |
| Cooling Input Power/Current | 2590Vl/11. 8 | 4450W/20.9A | 5000W/22.8A | | | |
| IPLV(H) | 2.71 | 2.71 | 2.71 | | | |
Working conditionA-7℃/6℃ W40℃~45℃ | Heating Capacity | 8500W | 15000W | 17000W | | | |
| COP | 3.2 | 3.2 | 3.2 | | | |
| Heating Input Power/Current | 2650W/12. 1 A | 4680W/20.4A | 5300W/24.4A | | | |
| Total Input Power | 3740W | 5800W | 6500W | | | |
| Total Input Current | 17A | 27A | 30A | | | |
| Water Flow | 1. 2m3/h | 2.06m3/h | 2.41m3/h | | | |
| Inlet & Outlet Pipe Size | DN25 | DN25 | DN25 | | | |
| Noise | ≤60dB(A) | ≤62dB(A) | ≤62dB(A) | | | |
| Net Weight | 90kg | 130KG | 135KG | | | |
| Dimensions | 990*380(430)*810mm | 1140*430(480)*1250mm | 1140*430(480)*1250mm | | | |