Поделиться:
Месяц | Минимальная цена | Макс. стоимость |
---|---|---|
Sep-16-2025 | 0.35 $* | 0.93 $* |
Aug-16-2025 | 0.67 $* | 0.3 $* |
Jul-16-2025 | 0.2 $* | 0.63 $* |
Jun-16-2025 | 0.23 $* | 0.65 $* |
May-16-2025 | 0.91 $* | 0.56 $* |
Apr-16-2025 | 0.48 $* | 0.74 $* |
Mar-16-2025 | 0.91 $* | 0.11 $* |
Feb-16-2025 | 0.8 $* | 0.7 $* |
Jan-16-2025 | 0.22 $* | 0.73 $* |
IDEAL-7700CHU series is the power solution to avoid data loss of your computers from power failure, with user-friendly LCD display and battery easy replacement design in a stand-alone unit. Embedded with 2 steps boost & 1 step buck AVR stabilizer, it is able to stabilize output voltage fluctuations and correct any abnormal voltages to protect connected devices. It offers comprehensive power protection against surges, spikes and over-voltage or under-voltage situations. With microprocessor control technology, it guarantees high reliability, which is suitable for home or small office applications.
* Auto-restart: UPS shuts down upon battery low and restarts automatically upon AC recovery
* Management software is designed to monitor and control UPS status (Optional)
* USB communication port and cable for managing functions via PC (Optional)
* Off mode charging: UPS charges itself even though power switch is off
* No-load shut down function (UPS Green Mode) for power saving
* 2-steps boost & 1-step buck AVR to stabilize output voltage
* Constant current, constant voltage battery charger
* Modem / phone line RJ-45 protection (Optional)
* Advanced microprocessor control technology
* Lightning / surge protection 175 joules
* Easy replacement battery design
* Over / under voltage protection Digital LCD 600VA UPS
* Smart USB charger
MODEL | IDEAL-7706CHU | IDEAL-7708CHU | ||
CAPACITY | 600VA/360W | 800VA/480W | ||
INPUT | ||||
Voltage | 110/115/120Vac or 220/230/240Vac | |||
Voltage Range | -30%+25% | |||
Frequency | 50Hz or 60Hz (Auto-Sensing) | |||
OUTPUT | ||||
Voltage Regulation | AC mode / Battery normal :110/115/120Vac or 220/230/240Vac +/- 10% | |||
Frequency | AC mode:47-53Hz for 50Hz or 57-63Hz for 60Hz ; Battery mode:50Hz or 60Hz +/- 1Hz | |||
Waveform | Simulated Sinewave | |||
Transfer Time | < 6ms(Typical) | |||
Outlet: Nema5-15R or Universal Nema | 4pcs back-up + 4pcs surge only | |||
Outlet : European | German or Universal or Australia or UK*2 pcs back-up & surge protected Italian*4 pcs back-up & surge protected | |||
Outlet : IEC-320 | IEC-320*4 pcs back-up & surge protected | |||
5VDC USB Charging | 2 ports 2.4A max. | |||
BATTERY | ||||
Voltage | 12VDC | |||
Type | 12V/7AH*1pcs | 12V/9AH*1pcs | ||
Recharge Time | 5 hours to 90% after complete discharge | |||
Safety Protection | Over Charge & Over Discharge Protection | |||
Advanced Battery Management | Yes | |||
DISPLAY | ||||
LCD Display | I/P & O/P Voltage & Frequency, Load %, Battery % | |||
MANAGEMENT | ||||
Smart USB | Software supporting Windows 95/98/NT/2000/ME/XP/2003/Vista/7/8/10 | |||
ENVIRONMENT | ||||
Operating Temperature | 0° C - 40° C (32° F~104° F) | |||
Humidity | 0-95% (Non-condensing) | |||
Acoustic Noise | < 40 dB at 1M |
IDEAL POWER CO., LTD was founded in 1996 and committed to design and manufacture reliable and qualified full range of power products, including Uninterruptible Power Supply (UPS), Inverter, Automatic Voltage Regulator (AVR), Voltage Protector (VP) and Surge Protector (SP).
With more than 20 years' experience of OEM/ODM in power products, IDEAL POWER strives to achieve the mission to provide products with high quality and better performance to meet customers' demand in the world.
We, IDEAL, are dedicating on product development and training professional team, we focus on the global market trend to provide innovative power for customers. IDEAL engineering team has professional background experience and technical knowledge and skill, devoting to integrate global market tendency with new technology to ensure products meet the global customer demand. IDEAL design team help customer design customized product package to establish admirable corporate image for marketing.
We are convinced that establishing long-term relationship of mutual trust and mutual benefit between IDEAL and customers is the motion for us to thrive.
With well-trained and professional team, IDEAL support best service and qualified products to customers globally.
1) ODM/OEM experience for more than 20 years.
2) Well-organized manufacturing bases to meet worldwide growing demand.
3) Customized products to meet various applications.
4) Full range of power products
5) High quality products supported by strict quality control system
6) Well-trained workforce and engineer team.
7) Reliable manufacturing supplier on E-commerce online platform
Q1: Why you should install UPS?
When AC Power is off, UPS will offer emergency back-up power to your electronic devices for data loss protection. Power surges are a threat everywhere. UPS can provide fully power protection for over-voltage, under-voltage and surge to offer smooth and consistent flow of power quality to your appliances.
Q2: What electronic appliances should be protected?
All electronic appliances that need long programming times or have to be always accessible would be better to install with a UPS system. This includes computer, medical equipment, data center, server room, networking system and any important electronic appliances.
However, it is not recommended to connect UPS with laser printer or office multifunction fax/printer because they will draw a high initial inrush current at start-up. A typical UPS cannot deal with such a spike.
Q3: What factors can affect UPS battery life time?
Batteries must be kept at ambient temperature of 25°C (77°F). If battery is operated at higher temperatures, its average life will be shortened. The number and length of battery discharges affect a battery's efficiency to deliver power. The more or deeper discharges, the shorter the battery's life will be.
If a battery is undersized for a load, battery run time and life expectancy will also be shortened.
Therefore, it is recommended to replace the batteries every 3 years after initiating the unit.
Recharge batteries every 3 months is necessary if it is not in use.
Данные ресурс не является интернет-магазином, а лишь содержит ссылки на международную торговую площадку Alibaba.com