WEH Series Electro-hydraulic Operated Directional control valve
WEH10 type of electro-hydraulic operated directional valve
The highest working pressure:P.A.B~31.5MPa | |||||||||||||||
T(Mpa) | Controlling oil external drain | 31.5 | |||||||||||||
Controlling oil internal drain | DC 21 AC 16 | ||||||||||||||
Y(Mpa) | Controlling oil external drain | DC 21 AC 16 | |||||||||||||
Minimum Control pressure(Mpa) | Controlling oil external supply Controlling oil internal supply (not suitable to C/Z/F/G/H/P/T/V) | Three-way valve 1 | |||||||||||||
Two-way valve with spring return 1 | |||||||||||||||
Two-way valve with hydraulic return 0.7 | |||||||||||||||
Controlling oil internal supply (not suitable to C/Z/F/G/H/P/T/V | 0.45 | ||||||||||||||
Maximum control pressure(Mpa) | 25 | ||||||||||||||
Liquid medium | Mineral oil,organic phosphate oil | ||||||||||||||
Oil temperature range (℃) | -30~+80(used to NBR seal) -20~+80(used to rubber seal)
| ||||||||||||||
Viscosity range(mm2/s) | 2.8~500 | ||||||||||||||
Control flow when switch(cm3) | Three-way valve 2.04 two-way valve 4.08 | ||||||||||||||
The total switch time of valve switching from zero position to switch position | |||||||||||||||
Control pressure(Mpa) | 7 | 14 | 21 | 25 | |||||||||||
AC | DC | AC | DC | AC | DC | AC | DC | ||||||||
Three-way valve(ms) | 30 | 65 | 25 | 60 | 20 | 55 | 15 | 50 | |||||||
Two-way valve(ms) | 35 | 80 | 30 | 75 | 25 | 70 | 20 | 25 | |||||||
The total switch time of valve switching from zero position to switch position | |||||||||||||||
Three-way valve(ms) | 30 | ||||||||||||||
Two-way valve(ms) | 35 | 40 | 30 | 35 | 25 | 30 | 20 | 25 | |||||||
The flow of minimum time switching(1/min) | AROUND35 | ||||||||||||||
Installation position | HC.HD.HK.HZ.HY with hydraulics return should be installed horizontally, | ||||||||||||||
weight | Single solenoid valve | 6.4 | |||||||||||||
double solenoids valve | 6.8 | ||||||||||||||
The regulator for timing the switch time | 0.8 | ||||||||||||||
Constant ratio pressure reducing valve | 0.5 |